Lightolier C7P38MH Work Light User Manual


 
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Job Information Type:
Calculite
®
HID Downlight C7P38MH
Page 2 of 2 7" Aperture, PAR38 Ceramic Metal Halide
CANDLEPOWER DISTRIBUTION
1,250
2,500
3,750
5,000
30°
60°
70W PAR38 FLOOD, PHILIPS 3K MH LAMP, LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
ANGLE MEAN CP LUMENS
0 22077
5 19279 1769
10 13483
15 7146 2166
20 2784
25 721 513
30 205
35 85 64
40 29
45 1 6
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 4446 92.65 98.46
0-40 4510 93.97 99.86
0-60 4516 94.1 100
0-90 4516 94.1 100
40-90 6 0.13 0.14
60-90 0 0 0
90-180 0 0 0
0-180 4516 94.1 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 59
55 0
65 0
75 0
85 0
** EFFICIENCY = 94.1% ** CERTIFIED TEST REPORT NO. 2419FR, DATE: JAN 26, 2004
SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 1.12 1.12 1.12 1.12 1.09 1.09 1.05 1.05 1.00 1.00 .94
1 1.09 1.07 1.06 1.05 1.06 1.03 1.02 1.00 .98 .97 .93
2 1.06 1.04 1.02 1.00 1.02 .99 .99 .96 .97 .94 .91
3 1.04 1.01 .98 .96 1.00 .96 .98 .94 .96 .93 .90
4 1.02 .98 .96 .94 .98 .93 .96 .92 .94 .91 .89
5 1.00 .96 .93 .91 .95 .91 .94 .90 .92 .89 .88
6 .99 .94 .91 .89 .94 .89 .93 .89 .92 .88 .87
7 .97 .92 .89 .87 .92 .87 .91 .87 .90 .86 .85
8 .95 .91 .88 .86 .90 .85 .89 .85 .89 .85 .84
9 .94 .89 .86 .84 .89 .84 .88 .84 .87 .84 .83
10 .92 .87 .85 .83 .87 .83 .87 .83 .86 .82 .82
LUMINAIRE INPUT WATTS = 78.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
100W PAR38 FLOOD, PHILIPS 3K MH LAMP, LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
ANGLE MEAN CP LUMENS
0 28361
5 26181 2386
10 19254
15 10393 3130
20 4124
25 1090 763
30 291
35 120 91
40 47
45 5 11
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 6278 92.33 98.41
0-40 6369 93.67 99.83
0-60 6380 93.82 100
0-90 6380 93.82 100
40-90 10 0.16 0.17
60-90 0 0 0
90-180 0 0 0
0-180 6380 93.82 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 231
55 0
65 0
75 0
85 0
** EFFICIENCY = 93.8% ** CERTIFIED TEST REPORT NO. 2421FR, DATE: JAN 21, 2004
SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 1.12 1.12 1.12 1.12 1.09 1.09 1.04 1.04 1.00 1.00 .94
1 1.09 1.07 1.06 1.04 1.05 1.03 1.01 1.00 .98 .97 .92
2 1.06 1.03 1.01 .99 1.02 .98 .99 .96 .96 .94 .91
3 1.04 1.00 .98 .96 .99 .95 .97 .94 .95 .92 .90
4 1.02 .98 .95 .93 .97 .92 .95 .91 .94 .91 .89
5 1.00 .96 .92 .90 .95 .90 .93 .89 .92 .89 .87
6 .98 .94 .91 .89 .93 .89 .92 .88 .91 .87 .86
7 .96 .92 .89 .87 .91 .86 .90 .86 .89 .86 .85
8 .95 .90 .87 .85 .89 .85 .89 .85 .88 .84 .83
9 .93 .88 .86 .84 .88 .84 .87 .83 .87 .83 .82
10 .92 .87 .84 .82 .87 .82 .86 .82 .86 .82 .81
LUMINAIRE INPUT WATTS = 110.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
70W PAR38 WIDE FLOOD, PHILIPS 3K MH LAMP. LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
ANGLE MEAN CP LUMENS
0 4860
5 4540 437
10 4365
15 4197 1180
20 3890
25 3162 1498
30 2735
35 1466 929
40 250
45 42 65
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3115 64.9 75.81
0-40 4044 84.26 98.42
0-60 4109 85.61 100
0-90 4109 85.61 100
40-90 64 1.35 1.58
60-90 0 0 0
90-180 0 0 0
0-180 4109 85.61 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 2104
55 0
65 0
75 0
85 0
** EFFICIENCY = 85.6% ** CERTIFIED TEST REPORT NO. 2420FR, DATE: JAN 26, 2004
SC = .9 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 1.02 1.02 1.02 1.02 1.00 1.00 .95 .95 .91 .91 .86
1 .98 .96 .94 .93 .95 .91 .91 .89 .88 .86 .82
2 .94 .91 .89 .86 .90 .85 .87 .83 .85 .82 .79
3 .91 .87 .83 .81 .85 .80 .84 .79 .82 .78 .75
4 .88 .83 .79 .76 .82 .76 .80 .75 .78 .74 .72
5 .84 .79 .74 .72 .78 .71 .76 .71 .75 .70 .68
6 .81 .75 .71 .68 .74 .68 .73 .67 .72 .67 .66
7 .78 .71 .67 .64 .71 .64 .70 .64 .69 .63 .62
8 .75 .68 .64 .61 .67 .61 .67 .61 .66 .60 .59
9 .71 .65 .60 .58 .64 .58 .63 .57 .63 .57 .56
10 .69 .62 .57 .54 .61 .54 .61 .54 .60 .54 .53
LUMINAIRE INPUT WATTS = 78.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
100W PAR38, WIDE FLOOD PHILIPS 3K MH LAMP, LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
ANGLE MEAN CP LUMENS
0 7868
5 7495 709
10 6849
15 6228 1761
20 5546
25 4296 2032
30 3425
35 1738 1130
40 296
45 69 84
50 2
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 4502 66.21 78.74
0-40 5632 82.83 98.51
0-60 5717 84.08 100
0-90 5717 84.08 100
40-90 84 1.25 1.49
60-90 0 0 0
90-180 0 0 0
0-180 5717 84.08 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 3439
55 0
65 0
75 0
85 0
** EFFICIENCY = 84.1% ** CERTIFIED TEST REPORT NO. 2422FR, DATE: JAN 21, 2004
SC = .8 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 1.00 1.00 1.00 1.00 .98 .98 .93 .93 .89 .89 .84
1 .97 .95 .93 .91 .93 .90 .89 .87 .86 .85 .81
2 .93 .90 .87 .85 .88 .84 .86 .82 .83 .81 .78
3 .90 .86 .82 .80 .84 .79 .83 .78 .81 .77 .75
4 .87 .82 .78 .76 .81 .75 .79 .74 .78 .74 .72
5 .83 .78 .74 .71 .77 .71 .76 .71 .75 .70 .68
6 .81 .75 .71 .68 .74 .68 .73 .68 .72 .67 .66
7 .77 .71 .68 .65 .71 .64 .70 .64 .69 .64 .63
8 .75 .68 .64 .62 .68 .61 .67 .61 .66 .61 .60
9 .71 .65 .61 .58 .65 .58 .64 .58 .63 .58 .57
10 .69 .62 .58 .56 .62 .56 .61 .55 .61 .55 .54
LUMINAIRE INPUT WATTS = 110.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
CANDLEPOWER DISTRIBUTION
12,500
25,000
30°
60°
CANDLEPOWER DISTRIBUTION
15,000
30,000
30°
60°
CANDLEPOWER DISTRIBUTION
2,000
4,000
6,000
8,000
30°
60°
18,750
22,500