Lightolier CXS Series 2x2 Work Light User Manual


 
CXS SERIES 2x2
CLEANGUARD CLASS 10,000 CLEAN ROOM
RECESSED FLUORESCENT
PHOTOMETRY MODEL NO. CXS2GFSVI26U120SO
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1696663 626058 595856
2635854 545148 525047
3575146 484441 464340
4534540 433835 413834
5484135 383430 373330
6453731 353027 343026
7423328 322724 312723
8393025 292421 282421
9362823 272219 262219
10 34 26 21 25 20 17 24 20 17
room cavity ratio
ORDERING INFORMATION
Explanation of Catalog Number. Example: CXS2GFSVI26U120SOGLR
CLEANGUARD
WET
LOCATION
Class 10,000
or
100,000
Clean Room
STATIC
FIXTURE
WIDTH
CEILING TYPE:
G= Grid (lay-in T bar)
F=Flanged (overlap) Z spline
and plaster frame
LENS FRAME:
FS= Flat steel frame
RA=Regressed
aluminum frame
FA=Flat aluminum
frame
LENS/SHIELDING TYPE:
VI=(virgin acrylic) .125
standard. For options
consult factory.
Smooth side of
lens towards room.
LAMP
QUANTITY:
2=2 Lamp
3=3 Lamp
LAMP/
FIXTURE LENGTH:
2U=T8, 1-5/8" U Lamp
17=T8, 2' Lamp
6U=6" U Lamp (T8)
FT=Twin Tube T5
(Nominal 24")
VOLTAGE:
120 or 277
BALLAST TYPE:
<
20THD <10THD
1-1 & 1-2 Lamp Elec. T8 SO* H
I*
1-3 Lamp Elec. T8 O3* H3*
1-1 & 1-2 Lamp Elec. TT5 SB*
IB*
(40 Watt)
1-3 Lamp Elec. TT5 X3* I3*
LOL T8 Dimming PS* -
LOL TT5 Dimming PB* -
*Instant Start Standard
OPTIONS:
Add appropriate suffix
to catalog no., ie: (GLR)
SPECIFICATIONS:
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing with side rails hemmed over and housing ends turned-in for safe
handling.
FINISH: Chassis exterior–black baked polyester enamel. Cavity–white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.
LENSES: VI (standard) extruded virgin acrylic, 3/16" square based female
cones, running 45° to the panel edge, .125" nominal thickness (similar to
pattern 12).
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non
PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and ULc Listed.
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
OPTIONS/ACCESSORIES
PLASTER FRAME: Catalog Number PF24.
CONTINUOUS ROW INSTALLATION: For F
type fixtures, half width flanges are required
between fixtures. Order Catalog Number:
S2FCTRIM (each joint).
FUSING: Internal fast-blow fusing.
SUFFIX: GLR.
Internal slow-blow fusing.
SUFFIX: GMF.
ELECTRICAL/WIRING OPTIONS:
Consult factory.
PRINTED IN USA 3/02
A Genlyte Thomas Company
Other dimming options. Consult factory.
TECHNICAL INFORMATION • (978) 657-7600
631 AIRPORT ROAD, FALL RIVER, MA 02720 • (508) 679-8131
C.F.I. DIVISION OF CANLYTE, INC.
525 EDUCATION ROAD, CORNWALL, ONTARIO
CANADA K6H 6C7 • (613) 938-6221
LER = FL - 56.0 IW - 53.7 BF - 0.87
Comparative yearly lighting energy cost per 1000 lumens = $4.24
CXS2GFSVI26U120SO
CX