Lightolier IC Series Work Light User Manual


 
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group SECTION 7/Folio Q80-10
Job Information Type:
IC
Standard IC Lens
IY
For NYC Code – I.B.E.W. Manufactured
IX
For NYC Code – Local 3 Manufactured
5½" Deep Body
0.0 45.0 90.0 FLUX
0 1708 1708 1708
5 1700 1698 1702 162
15 1620 1635 1655 462
25 1467 1501 1531 691
35 1231 1274 1328 798
45 904 959 1069 748
55 553 592 651 531
65 313 269 331 302
75 173 141 207 180
85 59 54 68 63
90 000
Model No. ICS2GFSVA26U120SO
LER = FP - 58.4 IW - 56.5 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $3.86
Report Number: G00036
Catalog Number: ICS2GFSVA26U120SO
Lamp: (2) T8 U6
Luminaire: IC 2' X 2' with VA lens
Ballast: M2-RN-T81LL-D-120
Report is based on 2750 Lumens per lamp.
Efficiency: 71.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.2
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.720 21.720
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4199. 4454. 4565.
55 3167. 3390. 3728.
65 2432. 2091. 2572.
75 2195. 1789. 2627.
85 2223. 2035. 2563.
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE LUMENS % LAMP % FIXT
00-030 1315 23.9 33.4
00-040 2113 38.4 53.7
00-060 3392 61.7 86.1
00-090 3938 71.6 100.0
90-180 00000.0000.0
00-180 3938 71.6 100.0
ZONAL LUMEN SUMMARY
Mounting Height
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
8.5 10 13 16 8.5 10 13 16
30x30 50 54 58 63 47 51 55 60
40x40 47 50 53 56 44 47 50 53
60x30 52 56 60 64 51 55 58 62
60x60 44 46 47 50 41 43 44 48
100x100 44 44 43 45 42 41 40 41
TYPICAL V.C.P.'s
Lens IC Series
Page 2 of 2 2' x 2' Recessed Fluorescent, IC Lens Frame Troffer
Static, 2-6" U Lamp T8
Options/Accessories
Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz.
average weight per square foot.
Radio Interference Filter:
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2.
(Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .76. To prevent
glare the VCP shall be not less than 41 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 2572 candelas per square meter. To control
veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.9%.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails
hemmed over and housing ends turned-in for safe handling.
Specifications (continued)
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86%
reflectance. Rust preventative undercoating.
Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge,
.095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use
wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws.
See: www.lamprecycle.org
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1797673716967686665
2726762636057615855
3666054565249545148
4615348514642494542
5574842464137444037
6534438423733413633
7494034383329373329
8463631353026343026
9433428322724322724
10 40 31 26 30 25 22 29 25 22
Lightolier is a Philips group brand
IC Series:
Recessed Lens
suitable for
Direct Thermal
Insulation
Contact
Body Style:
S=Static
Fixture
Width
Lens Shielding
Type:
VA=Virgin acrylic (standard),
see options and
consult factory
Voltage:
120, 277 or
UNV=120-277
Ceiling Type:
G= Grid
(lay-in T bar)
T= Slot grid
Lens Frame:
FS=Flat steel frame.
RA=Regressed
aluminum
frame.
FA=Flat aluminum
frame.
Lamp Type/
Fixture Length:
(By Others)
6U=6"U Lamp T8
(Nominal 24")
Lamp
Quantity
2=2 lamps
Ballast Type:
<20THD <10THD
1-2 Lamp Elec. T8 SO * HI *
*Instant Start Standard
NOTE:
For T8 UNV, you must use H
I
Ballast Code.
2S VA 6U
Options:
Lamps
Flex
EM Pack
Fuse
(Consult your
representative)
Ordering Information
Explanation of Catalog Number. Example: ICS2GFSVA26UUNVHI
-