Lincoln Electric 308 Welding Consumables User Manual


 
Product:
Blue Max Manual Electrodes
Date: 11/12/2008
Section VI - Health Hazard Data and Toxicological Properties
Acute Lethality Values: LC
50
means the concentration of a substance in air that when administered by means of inhalation over a specified length of time
in an animal assay, is expected to cause the death of 50% of a defined animal population.
LD
50
means the single dose of a substance that, when administered by a defined route in an animal assay, is expected to cause the death of 50% of
a defined animal population.
Threshold Limit Value: The ACGIH recommended general limit for Welding Fume NOS - (Not Otherwise Specified) is 5 mg/m
3
.
The TLV-TWA is the time-weighted average concentration for a normal 8-hour workday and a 40 hour workweek, to which nearly all workers may be
repeatedly exposed, day after day, without adverse effect. See Section VII for specific fume constituents which may modify this TLV. Threshold Limit
Values are figures published by the American Conference of Government Industrial Hygienists.
Effects of Overexposure: Electric arc welding may create one or more of the following health hazards:
Fumes and Gases can be dangerous to your health. Common entry is by inhalation. Other possible routes are skin contact and ingestion.
Short-term (acute) overexposure to welding fumes may result in discomfort such as metal fume fever, dizziness, nausea, or dryness or
irritation of nose, throat, or eyes. May aggravate pre-existing respiratory problems (e.g. asthma, emphysema). Chromates present in
the fume have been known to cause severe irritation of the bronchial tubes and lungs. Asthma has been reported. Exposure to
extremely high levels of fluorides can cause abdominal pain, diarrhea, muscular weakness, and convulsions. In extreme cases it can
cause loss of consciousness and death.
Long-term (chronic) overexposure to welding fumes can lead to siderosis (iron deposits in lung) and may affect pulmonary function.
Manganese overexposure can affect the central nervous system, resulting in impaired speech and movement. Bronchitis and some lung
fibrosis have been reported. Repeated exposure to fluorides may cause excessive calcification of the bone and calcification of ligaments
of the ribs, pelvis and spinal column. May cause skin rash. Chromates may cause ulceration and perforation of the nasal septum.
Liver damage and allergic reactions, including skin rash, have been reported. Chromates contain the hexavalent form of chromium.
Hexavalent chromium and its compounds are on the IARC (International Agency for Research on Cancer) and NTP (National
Toxicology Program) lists as posing a cancer risk to humans. Nickel and its compounds are on the IARC (International Agency for
Research on Cancer) and NTP (National Toxicology Program) lists as posing a cancer risk to humans. Nickel compounds are skin
sensitizers with symptoms usually occurring after repeated exposure - ranging from a slight itch to severe dermatitis. Respiratory
exposure to the crystalline silica present in this welding electrode is not anticipated during normal use. Respiratory overexposure to
airborne crystalline silica is known to cause silicosis, a form of disabling pulmonary fibrosis which can be progressive and may lead to
death. Crystalline silica is on the IARC (International Agency for Research on Cancer) and NTP (National Toxicology Program) lists as
posing a cancer risk to humans.
Arc Rays can injure eyes and burn skin. Skin cancer has been reported.
Electric Shock can kill. If welding must be performed in damp locations or with wet clothing, on metal structures or when in cramped positions such as
sitting, kneeling or lying, or if there is a high risk of unavoidable or accidental contact with workpiece, use the following equipment: Semiautomatic DC
Welder, DC Manual (Stick) Welder, or AC Welder with Reduced Voltage Control.
Section VII - Reactivity Data
Hazardous Decomposition Products: Welding fumes and gases cannot be classified simply. The composition and quantity of both are dependent upon
the metal being welded, the process, procedure and electrodes used.
Other conditions which also influence the composition and quantity of the fumes and gases to which workers may be exposed include: coatings on the metal
being welded (such as paint, plating, or galvanizing), the number of welders and the volume of the worker area, the quality and amount of ventilation, the
position of the welder's head with respect to the fume plume, as well as the presence of contaminants in the atmosphere (such as chlorinated hydrocarbon
vapors from cleaning and degreasing activities.)
When the electrode is consumed, the fume and gas decomposition products generated are different in percent and form from the ingredients listed in
Section III. Decomposition products of normal operation include those originating from the volatilization, reaction, or oxidation of the materials shown in
Section III, plus those from the base metal and coating, etc., as noted above.
Reasonably expected fume constituents of this product would include: Primarily fluorides and complex oxides of potassium, iron and silicon;
secondarily complex oxides of aluminum, chromium, manganese, nickel, sodium and titanium.
Maximum fume exposure guideline for this product (based on Cr (VI) content) is 0.08 milligrams per cubic meter.
Keep exposure as low as possible. Indoors, use local exhaust; outdoors, a respirator may be required.
Gaseous reaction products may include carbon monoxide and carbon dioxide. Ozone and nitrogen oxides may be formed by the radiation from the arc.
Determine the composition and quantity of fumes and gases to which workers are exposed by taking an air sample from inside the welder's helmet if worn or
in the worker's breathing zone. Improve ventilation if exposures are not below limits. See ANSI/AWS F1.1, F1.2, F1.3 and F1.5, available from the
American Welding Society, 550 N.W. LeJeune Road, Miami, FL 33126.
Section VIII - Preventive Measures and Precautions for Safe Handling and Use
Read and understand the manufacturer's instruction and the precautionary label on the product. Request Lincoln Safety Publication E205. See Canadian
Standards Association Standard CSA-W117.2 "Safety in Welding, Cutting, and Allied Processes" published by the Canadian Standards Association, 178
Rexdale Blvd., Rexdale, Ontario M9W1R3 for more details on many of the following:
Ventilation: Use enough ventilation, local exhaust at the arc, or both to keep the fumes and gases from the worker's breathing zone and the general area.
Train the welder to keep his head out of the fumes. Keep exposure as low as possible.
Respiratory Protection: Use respirable fume respirator or air supplied respirator when welding in confined space or general work area when local
exhaust or ventilation does not keep exposure below TLV.
Eye Protection: Wear helmet or use face shield with filter lens shade number 12 or darker. Shield others by providing screens and flash goggles.
Protective Clothing: Wear hand, head, and body protection which help to prevent injury from radiation, sparks and electrical shock. See W117.2.
At a minimum this includes welder's gloves and a protective face shield, and may include arm protectors, aprons, hats, shoulder protection, as well as dark
substantial clothing. Train the welder not to permit electrically live parts or electrodes to contact skin . . . or clothing or gloves if they are wet. Insulate from
work and ground.
Disposal Information: Discard any product, residue, disposable container, or liner as ordinary waste in an environmentally acceptable manner according
to Federal, State and Local regulations unless otherwise noted. No applicable ecological information available.
Section IX - Emergency and First Aid Procedures
Call for medical aid. Employ first aid techniques recommended by the Canadian Red Cross. IF BREATHING IS DIFFICULT give oxygen. IF NOT
BREATHING employ CPR (Cardiopulmonary Resuscitation) techniques. IN CASE OF ELECTRICAL SHOCK, turn off power and follow recommended
treatment. In all cases call a physician.