Lincoln Electric CV-305 Welder User Manual


 
C-1
ACCESSORIES
C-1
FACTORY INSTALLED
OPTIONS/ACCESSORIES
There are no factory installed options/accessories on
the CV-305.
FIELD INSTALLED OPTIONS
REMOTE VOLTAGE CONTROL (K857)
(1)
The K857 consists of a control box with 25 feet (7.6
m) of four conductor cable. Installation of a K857
Remote Voltage Control in the CV-305 requires a
K864 Remote Control Adapter. Refer to the instruc-
tions provided with the K857 for hookup to the CV-
305. When properly connected, and with the CV-305
Local-Remote Switch in the "Remote" position, the
K857 functions the same as the CV-305 Voltage
Adjust control, enabling minimum to maximum output
voltage adjustment of the CV-305.
(1)
Also availible is a K857-1 w/6 Pin MS-Type
(Amphenol) Plug and 100 feet (30.4m) cable.
TWO-CYLINDER UNDERCARRIAGE (K874)
Platform type undercarriage that can accommodate
either one or two gas bottles, or one gas bottle and a
Magnum water cooler. The CV-305 lifting eye is not
functional when the K874 undercarriage is installed.
UNIVERSAL ADAPTER (K867)
Provides a means of connecting auxiliary equipment
to the wire feeder receptacle on the CV-305 power
source. Consists of a 14-pin MS-type (Amphenol)
plug with 8 inch (0.2 meter) long flex leads, one for
each circuit present in the wire feeder receptacle. Not
required when using a standard wire feeder input
cable, such as a K480, with a Lincoln wire feeder.
TWIST-MATE CABLE PLUG (MALE)
• For 1/0-2/0 (50-70 mm
2
) Cable (K852-70)
• For 2/0-3/0 (70-95 mm
2
) Cable (K852-95)
TWIST-MATE CABLE RECEPTACLE
(FEMALE)
• For 1/0-2/0 (50-70 mm
2
) Cable (K1759-70)
• For 2/0-3/0 (70-95 mm
2
) Cable (K1759-95)
COMPATIBLE LINCOLN EQUIPMENT
The CV-305 is intended for use with the LF-72, LN-7,
LN-742, and LN-25 wire feed units. Use the Cables /
Kits listed below to make connection easily:
LF-72 Requires K1797-XX
Control Cable(Included with
Wire Feeder)
LN-7 / LN-7GMA Requires K480 Input Cable
LN-25
Requires K484 Jumper Plug Kit
LN-25 w/K444-1 Requires K864 Remote Control
Remote Voltage Adapter and K484 Jumper Plug
Control Kit Kit
LN-742 / LN-742H Requires K591 Input Cable
CV-305