Lincoln Electric IM491-B Welder User Manual


 
– 35 –
FIGURE 2
ELECTRIC TORCHES
Do not operate with covers removed
Disconnect input power before servicing
Do not touch electrically live parts
Only qualified persons should install,
use or service this equipment
THE LINCOLN ELECTRIC CO. CLEVELAND, OHIO U.S.A.
PILOT
WORK
ADAPTER
GAS LINE
WORK LEAD
PILOT LEAD
MOLEX CONNECTORS
CORD GRIP CONNECTOR
LOCK NUT
3. CONNECT PILOT LEAD.
MACHINE POWER SWITCH OFF.
1. DISCONNECT INPUT POWER TO THE PRO-CUT AND TURN
4. PLACE GAS LINE FITTING ON ADAPTER AND SCREW TIGHT.
2. INSERT TORCH CABLE THROUGH CASE FRONT OPENING.
USE LOCK NUT TO MOUNT CORD GRIP CONNECTOR.
5. ATTACH MOLEX CONNECTORS.
FOR LINCOLN
S19934
PLASMA TORCH CONNECTION DIAGRAM
5-28-93