Lincoln Electric IM604-B Welder User Manual


 
23
CONNECTION DIAGRAMS
23
RANGER 8 LPG
CONNECTION OF RANGER 8 TO LN-7 & K240 CONTACTOR KIT
WARNING: Turn the power off when making connections.
N.A. Use power source polarity switch to set for desired electrode
polarity. Position the output selector switch on the power
source to the CV position.
N.B. 3 conductor #16 power cord physically suitable for the instal-
lation and plug rated at 115 volts 15 amperes AC.
N.C. Plug into 115 volt AC receptacle on welder control panel or
other 115 volt AC supply rated at a minimum of 500 volt-
amperes.
N.D. Leads #21 and GND. do not appear on LN-7s with codes
below 7026.
N.E. Welding cables must be of proper capacity for the current
and duty cycle of immediate and future applications.
N.F. If LN-7 is equipped with a meter kit, extend lead #21 using
#14 or larger insulated wire physically suitable for the installa-
tion. An S16586-length remote voltage sensing work lead
GND. 32 2 4 31
TO LN-7
32
2
4
31
POWER
SOURCE
AUTO.
EQUIP.
WORK
ELECTRODE
POWER
SOURCE
75
76
77
K240 CONTACTOR KIT
21
115V (50/60HZ.)
(NOTE : 600 AMP CAPACITY)
ELECTRODE CABLE TO LN-7
TO WORK
CONTROL CABLE
CONNECT THE CONTROL CABLE
GROUND LEAD TO THE FRAME
THE TERMINAL STRIP OR TO
AN UNPAINTED FRAME SCREW.
N.D.
N.J.
N.F. & N.G.
N.B.
N.C.
TERMINAL MARKED NEAR
CONNECTION OF LN-7 & K240 CONTACTOR KIT WITH 115 VOLT AC AUXILIARY POWER AND CV OUTPUT
WELDER STANDARD OUTPUT TERMINALS
S17742
10-2-92
may be ordered for this purpose. Connect it directly to the
work piece independent of the welding work cable. For conve-
nience, this extended #21 lead should be taped to the welding
work lead.
N.G. Tape up bolted connection where lead #21 is extended.
N.H. Idler switch on power source must be in high idle position.
N.J. If an optional remote output control is used, connect it to this
terminal strip or 6 pin Amphenol receptacle. NOTE: Terminal
strip or 6 pin Amphenol receptacle not available on all power
sources.
CAUTION: Any speed up of the engine RPM by changing the gov-
ernor setting or over-riding the throttle linkage will cause an
increase in the AC auxiliary voltage. If this voltage goes
above 140 volts, the LN-7 control circuit will be damaged. The
engine governor setting is pre-set at the factory - do not
adjust above RPM specifications listed in engine welder oper-
ating manual.
M17486
ELECTRODE CABLE
LN-25
WIRE FEEDER
REMOTE CONTROL
TO WORK
ELECTRODE
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
TO WORK
WORK CLIP LEAD
TO WORK
6 PIN
AMPHENOL
N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH
IN "OUTPUT CONTROL REMOTE" POSITION.
RANGER 8 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM
CRM 21883
OPTIONAL K444-1
N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR
SWITCH TO THE WIRE FEED (CV) POSITION.
WARNING
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.