A-9
INSTALLATION
RANGER 305G
A-9
7. Set the "IDLE" switch to the "AUTO" position.
When not welding, the RANGER 305G engine will
be at the low idle speed. If you are using an LN-25
with an internal contactor, the electrode is not
energized until the gun trigger is closed.
8. When the gun trigger is closed, the current sens-
ing circuit will cause the RANGER 305G engine to
go to the high idle speed, the wire will begin to
feed and the welding process started. When weld-
ing is stopped, the engine will revert to low idle
speed after approximately 12 seconds unless
welding is resumed.
If you are using an LN-25 without an internal con-
tactor, the electrode will be energized when the
RANGER 305G is started.
------------------------------------------------------------------------
Connection of LN-742,K487-25 Spool Gun, and
Cobramatic to RANGER 305G
1. Shut the welder off.
2. Connect per instructions on the appropriate con-
nection diagram in Section F.
Connection of Prince Spool Gun
to the RANGER
350 G
Connection of the Prince XL Spool Gun requires the
use of the K1849-1 Adapter Module.
1. Shut the Welder off.
2. For electrode Positive, connect the electrode cable
to the "+" terminal of the welder and work cable to
the "-" terminal of the welder. For electrode
Negative, connect the electrode cable "-" terminal
of the welder and work cable to the "+" terminal of
the welder.
3. Connect the Control Cable of the Spool Gun to the
Adapter Module and connect the Control Cable of
the Adapter Module to the Welder.
4. Connect the Gas Hose.
5. Set the MODE switch to the "CV-WIRE " position.
6. Set the "WELD TERMINALS" switch to "WELD
TERMINALS ON"
7. Set the "ARC CONTROL" knob to "0" initially and
adjust to suit.
8. Set the "IDLE" switch to the "HIGH" position.
CAUTION