TROUBLESHOOTING
E-5
SAE-400
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
FUNCTION PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
No auxiliary power 1. Circuit Breakers open.
2. Faulty connections to auxiliary
receptacles.
3. GFCI Receptacle (if installed) may
have tripped.
1. Check and reset breakers. If
breakers keep tripping check con-
nections to auxiliary receptacles.
Also make sure load does nor
exceed receptacleʼs current rating.
2. Check connections.
3. Follow “GFCI Receptacle Testing
and Resetting Procedure” in the
MAINTENANCE section of this
manual.