Lincoln Electric IM904 Welder User Manual


 
INVERTEC STT II (CE)
A-1
INSTALLATION
A-1
STANDARD VOLTAGE INPUT CURRENT AT RATED OUTPUT
200/220/380/415/440/3/50/60 HZ 33/30/18/17/16
TECHNICAL SPECIFICATIONS –INVERTEC STT II (CE) (For Code 11366)
INPUT- THREE PHASE ONLY
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
INPUT VOLTAGE FUSE(SUPER LAG) INPUT AMPERE TYPE 75°C TYPE 75°C
AND FREQUENCY OR BREAKER RATING ON COPPER COPPER
SIZE NAMEPLATE SUPPLY WIRE GROUND WIRE
IN CONDUIT IN CONDUIT
AWG (IEC) SIZES
AWG (IEC) SIZES
200/50/60 40 33
220/50/60 40 30 10 (6 mm
2
) 10 (6 mm
2
)
380/50/60 30 18
415/50/60 30 17
440/50/60 30 16
HEIGHT WIDTH DEPTH WEIGHT
23.2 in 13.2 in. 24.4 in. 100 lbs.
589 mm 336 mm 620 mm 46 kg
OUTPUT
DUTY CYCLE AMPS VOLTS AT RATED AMPS
60% Duty Cycle 225 29
100% Duty Cycle 200 28
CURRENT RANGE OPEN CIRCUIT VOLTAGE AUXILIARY POWER
Peak Current
1
0 - 450 Amps 85 VDC Maximum 115
2
VAC @ 4 Amps
Background 0 - 125 Amps 42 VAC @ 4 Amps
1
At low input voltages (below 208 VAC) and input voltages of 380 VAC through 415 VAC there may be a 15% reduction in Peak Current.
2
115 VAC not present on European Models.
PHYSICAL DIMENSIONS