Lincoln Electric WELDING SYSTEMS Welding System User Manual


 
6
M PANEL
This optional control panel allows the user to select the type of
output desired: CV-MIG/CV Gas-Shielded, Flux-Cored
(Outershield,Metal-Cored), Flux-Cored (Innershield), or CC-
Stick (Soft)/Gouge. The “Arc Control “ varies inductance in the
CV modes and arc force in the CC-Stick mode.
Order K1542-6.
MSP2 PANEL
This optional control panel has the complete setup selections
of the MX panel. This panel also adds synergic CV and pulse
welding programs. Required to use Wave Designer software.
Order K1542-12.
MX2 PANEL
This optional control panel adds CC-Stick (crisp) mode and a
flexible welding setup.
Shielding gas preflow: 0.1 to 2.5 seconds or OFF.
Run-in wire feed speed: Adjustable for optimum start 75 to 150
inches per minute or OFF.
Arc Control: Inductance control adjusts arc characteristics to
operators preference.
Burnback: Time the arc stays on after the wire feed stops. 0.1
to 0.25 seconds or OFF.
Post Flow: Time the shielding gas flows after the weld stops.
0.1 to 10.0 seconds or OFF.
Crater Fill: Allows a second procedure used in the 4-step
trigger mode. Use for aluminum crater fill welding or a
second procedure.
Order K1542-11.
OPTIONAL
CONTROL PANELS
PROCESS CONTROL PANELS
POWER FEED 10 & 10 DUAL