Lincoln Electric SP-135T Welder User Manual


 
A-6
INSTALLATION
SP-135T
A-6
INPUT CONNECTIONS
Refer to Figure A.6.
The SP-135T has a power input cable located on the
rear of the machine.
FIGURE A.6
CODE REQUIREMENTS FOR INPUT
CONNECTIONS
This welding machine must be connected to a
power source in accordance with applicable elec-
trical codes.
The National Electrical Code provides standards
for amperage handling capability of supply con-
ductors based on duty cycle of the welding
source.
If there is any question about the installation
meeting applicable electrical code requirements,
consult a qualified electrician.
Requirements For Rated Output
A power cord with a 15 amp, 125 volt, three prong
plug (NEMA Type 5-15P) is factory installed on the
SP-135T. Connect this plug to a mating grounded
receptacle which is connected to a 20 amp branch cir-
cuit with a nominal voltage rating of 115 to 125 volts,
60 Hertz, AC only.
The rated output with this installation is 90 amps,19
Volts, 20% duty cycle (2 minutes of every 10 minutes
used for welding).
Do not connect the SP-135T to an input power
supply with a rated voltage that is greater than 125
volts.
Do not remove the power cord ground prong.
POWER INPUT
CABLE
GAS SOLENOID
INLET FITTING
WARNING
CAUTION