I
I
.i
Connecting air hose
Lock
the
trigger.
Slip the
air
socket
of
the
air
hose
onto
the
air
fitting
on the nailer.
Be
sure
that
the
air
socket locks firmly into position when installed onto
the
air
fitting.
A
hose coupling must be installed on
or
near the tool
in
such
a
way
that
the pressure reservoir
will
discharge
at
the
time
the
air
supply coupling
is
dis-
connected.
r
Operation
I
I
Release
the
trigger
by
turning
the
lock
knob.
Place
the
driver guide
agianst
the
workpiece
and
pull the trigger. Nails will be driven into the workpiece. When nails are depleted, the trigger
cannot be pulled because
a
mechanism actuates. Load nails into the magazine, and the trigger
can now be pulled.
CAUTION
:
.The mechanism cannot actuate when the slide door is open.
So
always lock the trigger by
turn-
Operating the tool without nails shortens the life of the tool and should be avoided.
ing
the lock knob to prevent accidental
firing
when the slide door is open.
Air exhaust
Air
exhaust direction can be changed easily by rotating
the exhaust cover. Change
it
when necessary.
Jammed nailer
When the nailer becomes jammed, proceed as follows:
1.
First, lock the trigger and disconnect the hose.
2.
Remove the three screws which secure the driver
3.
Remove the jammed
nail
from the ejection slot.
To reassemble the tool, perform the above operations
in
reverse sequence.
guide. Remove the driver guide.
xhaust
cover
13