Makita HM1213C Power Hammer User Manual


 
4
loose easily, causing a breakdown or accident.
Check tightness of screws carefully before
operation.
7. In cold weather or when the tool has not been
used for a long time, let the tool warm up for a
while by operating it under no load. This will
loosen up the lubrication. Without proper
warm-up, hammering operation is difficult.
8. Always be sure you have a firm footing.
Be sure no one is below when using the tool in
high locations.
9. Hold the tool firmly with both hands.
10. Keep hands away from moving parts.
11. Do not leave the tool running. Operate the tool
only when hand-held.
12. Do not point the tool at any one in the area
when operating. The bit could fly out and
injure someone seriously.
13. Do not touch the bit or parts close to the bit
immediately after operation; they may be
extremely hot and could burn your skin.
14. Do not operate the tool at no-load
unnecessarily.
15. Some material contains chemicals which may
be toxic. Take caution to prevent dust
inhalation and skin contact. Follow material
supplier safety data.
SAVE THESE INSTRUCTIONS.
WARNING:
MISUSE or failure to follow the safety rules stated in
this instruction manual may cause serious personal
injury.
USD203-2
Symbols
The followings show the symbols used for tool.
volts
amperes
hertz
alternating current
Class II Construction
revolutions or reciprocation per minute
number of blow
FUNCTIONAL DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and unplugged
before adjusting or checking function on the tool.
Switch action
ON
OFF
1
009947
CAUTION:
Before plugging in the tool, always check to see
that the tool is switched off.
Switch can be locked in "ON" position for ease of
operator comfort during extended use. Apply
caution when locking tool in "ON" position and
maintain firm grasp on tool.
To start the tool, push the switch lever "ON (I)" on the left
side of the tool. To stop the tool, push the switch lever
"OFF (O)" on the right side of the tool.
Speed change
1
009955
The blows per minute can be adjusted just by turning the
adjusting dial. This can be done even while the tool is
running. The dial is marked 1 (lowest speed) to 5 (full
speed).
Refer to the table below for the relationship between the
number settings on the adjusting dial and the blows per
minute.
Number on adjusting dial Blows per minute
5
4
3
2
1
1,900
1,700
1,450
1,200
950
009956
1. Adjusting dial
1. Switch lever