After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Compressor does not run:
• No mains voltage.
− Check cables, plug, outlet and
mains fuse.
• Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
device.
• Compressor was stopped by
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
• Motor has overheated, caused by
insufficient cooling (cooling fins
covered).
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
• Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain screw(s);
replace if necessary.
− Tighten drain screw(s) fingertight.
• Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
• Pressure regulator not opened wide
enough.
− Open pressure regulator more.
• Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The device's packaging can be 100 %
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
7. Repairs
8. Environmental Protection
9. Technical Specifications
Suction capacity l/min 235
Free air delivery (volume flow rate) l/min 110
Filling rate l/min 120
Max. working pressure bar 8
Pressure vessel volume l 4
Pump model F 245
No. of cylinders 1
Motor speed min
-1
2850
Motor capacity kW 1.5
Supply voltage (50 Hz) V 230
Rated current A 6.8
Fuse protection min. A 10 (time-lag)
Degree of protection IP 20
Maximum overall length when using extension cables with:
– 3 x 1.0 mm
2
lead cross-section
– 3 x 1.5 mm
2
lead cross-section
– 3 x 2.5 mm
2
lead cross-section
m
m
m
10
25
25
Dimensions: length x width x height mm 600 x 310 x 405
Weight kg 18
Sound pressure level at 1 m max. dB (A) 87 ± 3