Miller Electric 500D Welder User Manual


 
OM-4428 Page 37
7-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)
1 Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 5-12).
0774 / Ref. 215 664 / Ref. 803 602
Example: Combination Remote Amperage Control (Stick)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range Control Not
Used In Remote
Stick Mode
Set Remote
Process
Example: Combination Remote Amperage Control (TIG)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range Set Control
Set Remote
Process
1
In Example:
Process = Stick (Using Remote On/Off)
Range = 110 to 390 A DC
Min = 110 A DC
Max = 390 A DC
Max (390 A DC)
Min (110 A DC)
In Example:
Process = TIG (Using Remote On/Off)
Range = 35 to 320 A DC
Percentage Of Range = 50%
Min = 35 A DC
Max = About 178 A DC (50% of 35 to 320)
Max (178 A DC)
Min (35 A DC)