Miller Electric 575Volt Welder User Manual


 
OM-188 304 Page 31
Program 11 −− .045 Metal Core −− Recommended Gases: Argon/CO
2
Gas: Argon/CO
2
mixes up to 20% CO
2
IPM Trim Peak Amp Background Amp Freq. Pulse Width Starting Amps
100 0 310 45 50 2.30 529
145 10 330 61 65 2.45 529
190 20 354 70 90 2.55 529
235 30 365 78 110 2.65 529
280 40 370 89 130 2.75 529
325 50 376 100 150 2.85 529
370 60 381 111 165 3.00 529
415 70 385 122 180 3.15 529
460 80 390 138 190 3.25 529
505 90 395 155 200 3.35 529
550 100 400 175 205 3.45 529
Program 12 −− .052 Metal Core −− Recommended Gases: Argon/CO
2
Gas: Argon/CO
2
mixes up to 20% CO
2
IPM Trim Peak Amp Background Amp Freq. Pulse Width Starting Amps
60 0 360 36 40 2.00 529
99 10 365 70 50 2.10 529
138 20 370 94 73 2.20 529
177 30 374 116 94 2.35 529
216 40 379 133 112 2.50 529
255 50 384 147 129 2.65 529
294 60 387 160 144 2.85 529
333 70 390 174 159 3.00 529
372 80 393 186 174 3.15 529
411 90 396 199 189 3.35 529
450 100 400 210 204 3.50 529