SECTION 5 OPERATION
5-1. Power Switch
1 Power Switch
1
Ref. 803 183
1 Left/Right Select Switch
Pressing the Left/Right Select
switch allows the operator to
choose which side of the unit’s con-
trols will operate.
5-2. Left/Right Select Switch
1
Ref. 803 184
5-3. Jog/Purge
1
Ref. 803 184
2
1 Jog/Purge Push Buttons
2 Wire Speed Controls
Pressing the Jog/Purge switch allows the op-
erator to jog wire without energizing the weld
power or gas valve circuit.
The unit provides the ability to jog the wire
feeder by means of the gun trigger or the
Jog/Purge switch. If the welding arc does
not initiate in 3 seconds after the gun trigger
is activated, the unit will perform a jog opera-
tion for a maximum of two minutes. If the gun
trigger is still activated after two minutes, the
jog operation is terminated to prevent com-
plete despooling of the wire, in the case of
a damaged gun.
The unit displays the “ERR TRIG“ message
to inform the operator that the trigger is acti-
vated.
Jog speed can be adjusted by the Adjust
control when the unit is jogging wire. The
unit displays jog speed when the unit is be-
ing jogged.
Jogging can also be accomplished by
pressing the Jog/Purge button.
Pressing the Jog/Purge button also allows
the operator to purge gas lines before weld-
ing and to preset gas pressure at the
regulator.