Miller Electric and SS-74D16 Welder User Manual


 
OM-150011 Page 18
5-4. Trigger Hold Switch
1 Trigger Hold Switch
Trigger hold allows the operator to weld with-
out holding the gun trigger.
To use the trigger hold function, place the
trigger hold switch in the On position.
The operator must hold the trigger for a mini-
mum of 2 seconds, but not longer than 6
seconds before releasing it. Welding will
continue when the trigger is released.
To stop welding, press the trigger again.
1
803 152
5-5. Voltage Control And Digital Meters (For Models With Meters Only)
3
803 152
1
2
1 Voltmeter
Displays actual or preset voltage
from welding power source through
the 14pin control cable.
2 Wire Speed Meter
Factory set to display inches per
minute. If display of meters per min-
ute is desired, see Section 4-13.
3 Voltage Control
Use control to adjust voltage output
of welding power source.