OM-4427 Page 13
4-3. Volt-Ampere Curves For CC Models
215 081-A
The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
DC AMPERES
DC VOLTS
100
80
60
40
20
0
0 100 200 300 400 500 600 700 800 900 1000
Ranges:
230 − Max
170 − 365
110 − 225
70 − 130
55 − 85