3-3. Remote Movement Control Connections
ST-154 577
Slide movement can be controlled
by a remote device having a set of
normally-open contacts. Timing of
the contact closure is controlled by
the remote device.
1 MSC-2 Control
Open control door.
2 Strain Relief
3 Cord From Remote Device
Crimp proper terminals onto leads.
4 Terminal Strip 1T
Make connections, tighten strain
relief, and close and secure door.
A
B
C
D
E
F
G
H
J
K
F is circuit common
G to F = Up
H to F = Down
J to F = Right
K to F = Left
Tools Needed:
1
2
3
4
4
3-4. Installing Gun Onto Mounting Plate
Ref. ST-154 578
A remote gun mount can be used to
install gun to slide.
1 Gun Mounting Plate
2 4-1/4 in. (108 mm)
3 4-1/4 in. (108 mm)
4 3/816 UNC Tapped Holes
Do not use screws longer than 1/2