Miller Electric 456 CC Welder User Manual


 
OM-188 422 Page 17
3-7. Remote 14 Receptacle Information
Socket* Socket Information
24 VOLTS AC
A 24 volts ac. Protected by circuit breaker CB2.
24 VOLTS AC
B Contact closure to A completes 24 volts ac con-
tactor control circuit.
AJ
B
K
I
115 VOLTS AC
I 115 volts ac. Protected by circuit breaker CB1.
B
C
L
NH
D
M
G
115 VOLTS AC
J Contact closure to I completes 115 volts ac con-
tactor control circuit.
E
F
C Output to remote control; +10 volts dc in MIG
mode.
D Remote control circuit common.
REMOTE
OUTPUT
CONTROL
E 0 to +10 volts dc input command signal from re-
mote control.
M Mode select.
N Remote inductance control.
A/V
AMPERAGE
F Current feedback; +1 volt dc per 100 amperes.
Ref. ST-802 260
AMPERAGE
VOLTAGE
H Voltage feedback; +1 volt dc per 10 arc volts.
G Circuit common for 24 and 115 volts ac circuits.
GND
K Chassis common.
*The remaining sockets are not used.