OM-4407 Page 22
5-10. Adjusting Wire (MIG) Weld Puddle Consistency
803 099
3/8, 7/16 in
Tools Needed:
1
3
2
Y Stop engine and let cool.
Stabilizer DC-Z is factory connected to suit
most Wire (MIG) welding applications.
To change Wire (MIG) weld puddle consis-
tency, proceed as follows:
Remove cover and right side panel.
1 Stabilizer DC-Z
2 Wire /CV Weld Output Terminal
3 Stabilizer Leads 29, 28, And 27
Lead 29 − provides stiffest weld
puddle
Lead 28 − provides wetter weld
puddle (for mild steel)
Lead 27 − provides wettest weld
puddle (for stainless steel)
Lead 29 is connected to the Wire/CV weld
output terminal at the factory.
Disconnect lead 29 from the Wire/CV weld
output terminal.
For wetter weld puddle (for mild steel):
Remove insulated sleeving from lead 28.
Connect lead 28 to Wire/CV weld output ter-
minal, reusing hardware. Insulate lead 29
with sleeving removed from lead 28. Secure
sleeving with cable ties.
For wettest weld puddle
(for stainless steel):
Remove insulated sleeving from lead 27.
Connect lead 27 to Wire/CV weld output ter-
minal, reusing hardware. Insulate lead 29
with sleeving removed from lead 27. Secure
sleeving with cable ties.
Reinstall side panel.