Norcold N84X.3 Work Light User Manual


 
www.norcold.com/cda 65N6XX/N8XX ModelsRefrigerator Service Manual
1
7
4
DC voltage normal
DC voltage higher than 15.4 volts
DC voltage lower than 10.5 volts
Screen
Number
1
7
4
AC voltage normal
AC voltage higher than 132 volts
AC voltage lower than 108 volts
Screen
Number
1
2
3
4
5 6
AC power to AC heater
DC power to divider heater
DC power to gas valve
DC power to ignition circuit
DC power to DC heater*
DC power to light switch
Screen
Number
*3-way models
1
2
3
Sensing burner flame
Food comparment light
is off and door is closed
Thermistor sensing
fin temperature
Screen
Number
Screen Power Board Inputs
Screen 7 displays "live" power board inputs using
lighted LED segments. The illustration below provides
"live" inputs information and assigned LED segments. If a
power board input is active or "live," its assigned
input LED will be on.
Press the
MODE
button to bring up screen 0.
Screen Power Board Outputs
Screen 8 displays "live" power board outputs using
lighted LED segments. The illustration below provides
"live" outputs information and assigned LED segments.
If a power board output is active or "live," its
assigned output LED will be on.
Screen Power Board DC Voltage Status
Screen 9 displays DC voltage status using lighted LED
segments. The illustration below provides DC voltage
status information and assigned LED segments. If DC
voltage at the power board within normal range (10.5
to 15.4 Vdc), LED segment 4 will be on.
Screen Power Board AC Voltage Status
Screen 0 displays AC voltage status using lighted LED
segments. The illustration below provides AC voltage
status information and assigned LED segments. If AC
voltage at the power board within normal range (108
to 132 Vac), LED segment 4 will be on.
Press the
MODE
button to return to screen 1.
Press the
MODE
button to bring up screen 8.
Press the
MODE
button to bring up screen 9.