Omega CNiS16 Stud Sensor User Manual


 
61
Approvals
UL, C-UL and see CE Approval Section
GENERAL
Line Voltage/Power
90-240 Vac +/-10%, 50-400 Hz*
110-375 Vdc, equivalent voltage
4 W power for iS8, iS8C, iS16, iS32
5 W, power for iS8DV, iS8DH, iS16D
* No CE compliance above 60 Hz
Low Voltage/Power Option
12-36 Vdc, 3 W**
power for iS8, iS8C,
iS16, and iS32
20-36 Vdc, 4 W
, power for iS8DV, iS8DH,
and iS16D
External power source must meet
Safety Agency Approvals.
** Units can be powered safely with 24 Vac
power but, no Certification for CE/UL are
claimed.
External Fuse Required
Time-Delay, UL 248-14 listed:
100 mA/250 V
400 mA/250 V
(Low Voltage/Power Option)
Time-Lag, IEC 127-3 recognized:
100 mA/250 V
400 mA/250 V
(Low Voltage/Power Option)
Environmental Conditions
•All models: 0 to 55 °C (32 to 131 °F),
90% RH non-condensing
•iS8DV, iS8DH, iS8C, iS16D:
0 to 50 °C (32 to 122 °F) for UL only,
90% RH non-condensing
Protection
NEMA-4x/Type 4x/IP65 front bezel:
iS32, i1S6D, iS8C
NEMA-1/Type 1 front bezel: iS8, iS8DH,
iS8DV
Dimensions
i/8 Series:
48 H x 96 W x 127 mm D
(1.89 x 3.78 x 5")
i/8 Compact Series:
48 H x 96 W x 74 mm D
(1.89 x 3.78 x 2.91")
i/16 Series: 48 H x 48 W x 127 mm D
(1.89 x 1.89 x 5")
i/32 Series:
25.4 H x 48 W x 127 mm D
(1.0 x 1.89 x 5")
Panel Cutout
i/8 Series:
45 H x 92 W mm (1.772" x 3.622 "),
1/8 DIN
i/16 Series: 1/16 DIN
45 mm (1.772") square
i/32 Series:
22.5 H x 45 W mm (0.886" x 1.772"),
1/32 DIN
Weight
i/8 Series: 295 g (0.65 lb)
i/16 Series: 159 g (0.35 lb)
i/32 Series: 127 g (0.28 lb)