Panasonic SD51C94JBU6 Air Compressor User Manual


 
Suction
Tube
Tube
Process
Discharge
Tube
19mm (.75") DIA
4 Holes
16mm (.63") DIA
4 Holes
207.1mm (8.15")
170mm (6.69")
165.1mm (6.50")
70mm
(2.76")
101.6mm
(4.00")
130.6mm
(5.14")
150.4mm
(5.92")
82mm
(2.44")
87mm (3.43") 78mm (3.07")
104mm (4.09")
76mm
(2.99")
41mm
(1.61")
164.4mm (6.47") DIA
C
D
B
A
2.5mm (.10")
E
D
Dimensions*
mm inches
A
. . . . . . . . . . . . . . . . . . . . . 172.1 . . . . . . . . . . . . . . . . . . . 6.78
B
. . . . . . . . . . . . . . . . . . . . . 60.9 . . . . . . . . . . . . . . . . . . . . 2.40
C
. . . . . . . . . . . . . . . . . . . . . 111.2 . . . . . . . . . . . . . . . . . . . 4.38
D
. . . . . . . . . . . . . . . . . . . . . 102.0 . . . . . . . . . . . . . . . . . . . 4.02
E
. . . . . . . . . . . . . . . . . . . . . 85.0 . . . . . . . . . . . . . . . . . . . . 3.35
*
All dimensions are for reference only
Tubes Tube O.D. Wall Material
Suction . . . . . . . 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper
Process . . . . . . 0.3125 in / 7.94 mm 0.028 in. / 0.7 mm Copper
Discharge . . . . . 0.28 in. / 7.0 mm 0.041 in. / 1.05 mm Copper
U.L. File # . . . . . . . . . SA 4615
C.S.A. File #’s . . . . . . LR - 36593
General Data Oil Charge . . 195 cc ± 5 cc / 11.9 cu.in.± 0.3 cu.in.
Net Weight With Oil . . . . . . . . . . . . 16.3 lbs, 7.4 kg
Approved Oils . . . . . . FREOL α 10, FREOL α 10E
. . . . . . .FREOL α 22, FREOL α 22E
Residual Moisture . . . . . . . . . . . . . . . 120 mg max.
Impurities . . . . . . . . . . . . . . . . . . . . . . . 7 mg max.
Displacement . . . . . . . . . . . 5.10 cc. / 0.311 cu. in.
Panasonic Industrial Company
Refrigeration Products Department
Tel: 201 - 392 - 4249
Fax: 201 - 392 - 4315 Rev#1-5/9
This document sets forth certain operational parameters and conditions for
operation of this product. If this product is operated outside of the parameters
and conditions stated herein, buyer assumes sole and full responsibility and
shall indemnify seller with respect to all product failures and all consequences
thereof. Operation of the product outside of the parameters and conditions
specified herein shall serve to invalidate all seller warranties, if any, with respect
to the product. This document is for reference only. For specifications, please
contact Panasonic’s engineering department.
MATSUSHITA Compressor Single Phase 115 V
MODEL# SD51C94JBU6 (15µF Run Cap. - VG10) R-134a 60 Hz
P
a
na
s
o
n
ic
®
Running
Capacitor
M
C
S
~
2
8
7
56
3
Compressor
Motor
R.S.C.R.
Internal Motor Protector