Pantech GX Series Stud Sensor User Manual


 
GF Specifications GF-200 GF-300 GF-1200 GF-2000 GF-3000 GF-6000
Weighing Capacity
Resolution
Repeatability
Linearity
Stabilization time
Sensoring method
Display type
Sensitivity drift
(10° C to 30° C/50° F to 80° F)
Counting Mimimum unit mass
mode Number of samples
Percent
Minimum 100% reference mass
mode Minimum 100% display
Weighing units & modes
Display refresh rate
Operating environment temperature
External dimensions
AC adapter
Power consumption
Standard serial I/F
External calibration weight to be used
Weighing pan
Net weight
210g 310 g 1210g 2100g 3100g 6100g
0.001g 0.01g 0.1g
0.001g 0.01g 0.1g
±0.002g ±0.02g ±0.1g
Approx. one second (Typ. FAST response setting)
Super Hybrid Sensor (SHS)
Vacuum Fluorescent Display (VFD)
± 2ppm/°C ± 5ppm/°C
0.001g 0.01g 0.1g
5, 10, 25, 50 or 100 pieces
0.100g 1.00g 10.0g
0.01%, 0.1%, 1% (depends on reference mass stored)
g, PC, PCT, OZ, Lb, L Oz, Ozt, ct, mm, dwt, GN, TL, DS, Mit, newtons
5 times / second or 10 times / second
5° C to 40° C (41° F to 104° F), 85 % RH or less (No condensation)
210 (W) x 317 (D) x 86 (H) mm
Confirm that the adapter type is correct for the local voltage and power receptade
Approx. 11VA (supplied by AC adapter)
RS-232C interface with WinCT (WinCT: included as CD-ROM)
200g 300g 1000g 2000g 3000g 6000g
100g 200g 500g 1000g 2000g 5000g
100g 1000g 4000g
3000g
2000g
128 x 128 mm 165 x 165 mm
Approx. 3.8kg Approx. 4.3kg
GX Specifications
GX-200-EC GX-400-EC GX-600-EC GX-2000-EC GX-4000-EC GX-6100-EC GX-6000-EC GX-8000-EC
Weighing Capacity (Max)
Resolution (d)
Repeatability
Linearity
Stabilization time
Sensoring method
Display type
Sensitivity drift
(10° C to 30° C/50° F to 86° F)
Counting Mimimum unit mass
mode Number of samples
Percent Minimum 100% reference mass
mode Minimum 100% display
Weighing units & modes
Display refresh rate
Operating environment temperature
External dimensions
AC adapter
Power consumption
Standard serial I/F
External calibration weight to be used
Calibration
Net weight
210g 410 g 610g 2100g 4100g 6100g 6100g 8100g
0.001g 0.01g 0.1g
0.001g 0.01g 0.1g
±0.002g ±0.003g ±0.02g ±0.03g ±0.1g
Approx. 1 second
Approx. 1.5 s Approx. 1 second
Super Hybrid Sensor (SHS)
Vacuum Fluorescent Display (VFD)
± 2ppm/°C (When automatic self calibration is not used)
± 5ppm/°C (auto-self calibration OFF)
0.001g 0.01g 0.1g
5, 10, 25, 50 or 100 pieces
0.100g 1.00g 10.0g
0.01%, 0.1%, 1% (depends on reference mass stored)
g, PC, PCT, OZ, Lb, L Oz, Ozt, ct, mm, dwt, GN, TL, DS, Mit, newtons
5 times / second or 10 times / second
5° C to 40° C (41° F to 104° F), 85 % RH or less (No condensation)
210 (W) x 317 (D) x 86 (H) mm
Confirm that the adapter type is correct for the local voltage and power receptade
Approx. 11VA (supplied by AC adapter)
RS-232C interface with WinCT (WinCT: included as CD-ROM)
200g 400g 600g 2000g 4000g 6000g 6000g 8000g
100g 300g 500g 1000g 3000g 5000g 5000g 7000g
200g 400g 2000g 4000g 4000g 6000g
300g 3000g 3000g 5000g
4000g
Motor-driven internal calibration with SHS
Approx. 4.6kg Approx. 5.1kg