Philips 146498 Work Light User Manual


 
Footnotes:
1) Measured at 100 hours of life in horizontal position.
2) Approximate lumen values listed are for horizontal operation of lamp.
3) Approximate mean lumen output at 40% of lamp rated average life.
4) Rated average life is the life obtained,on the average,from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start.
It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
5) Measured at rated lamp watts on a linear reactor.LPW does not include ballast losses.
6) Measured with the lamp operating at rated watts.
Electrical Data (Subject to change without notice)
Warnings,
Cautions and Operating Instructions
“WARNING:These lamps can cause serious skin burn and eye inflammation
from short wave ultraviolet radiation if outer envelope of the lamp is broken
or punctured.Do not use where people will remain for more than a few minutes
unless adequate shielding or other safety precautions are used.Certain lamps
that will automatically extinguish when the outer envelope is broken or punctured
are commercially available.” This lamp complies with FDA radiation performance
standard 21 CFR subchapter J.(USA:21CFR 1040.30 Canada: SOR/DORS/80-381)
If the outer bulb is broken or punctured,turn off at once and replace
the lamp to avoid possible injury from hazardous short wave ultraviolet
radiation.Do not scratch the outer bulb or subject it to pressure as this
could cause the outer bulb to crack or shatter
.A partial vacuum in the
outer bulb may cause glass to fly if the envelope is struck.
WARNING:
The arc-tube of metal halide lamps is designed to operate under high
pressure and at temperatures up to 1000ºC and can unexpectedly rupture due to
internal or external factors such as a ballast failure or misapplication.If the arc-tube
ruptures for any reason,the outer bulb may break and pieces of extremely hot glass
might be discharged into the sur
r
ounding en
vironment. If such a rupture were to
ha
ppen,
THERE IS
A RISK OF PERSONAL INJURY,PROPERTY DAMAGE,
B
URNS AND FIRE.
These lamps are designed to retain all the glass particles should an arc tube
rupture occur. The following operating instructions are recommended to
minimize these occurrences.
RELAMP FIXTURES
A
T OR BEFORE THE END OF RATED LIFE.
Allo
wing lamps to operate until the
y fail is not advised and may
incr
ease the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing less than
25 nCi of Kr-85 and is distributed by Philips Lighting Company,a
division of Philips Electronics North America Corporation, Somerset,
New Jersey 08875-6800.
CA
UTION:
T
O REDUCE
THE RISK OF PERSONAL INJURY,PROPERTY
D
AMA
GE,BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE
FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED.
Lamp Operating Instructions:
1
)
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing lamps
to operate until they fail is not advised and may increase the possibility
of inner arc tube rupture.
2
)
Before lamp installation/replacement,shut power off and allow lamp and fixture
to cool to avoid electrical shock and potential burn hazards.
3) Use only auxiliary equipment meeting Philips and/or ANSI standards.
Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers electrical data.
4) Periodically inspect the outer envelope.Replace any lamps that show scratches,
cracks or damage.
5) If a lamp bulb support is used,be sure to insulate the support electrically
to avoid possible decomposition of the bulb glass.
6)
Pr
otect lamp base
,
socket and wiring against moisture,corrosive atmospheres
and excessiv
e heat.
7)
Time should be allo
w
ed f
or lamps to stabilize in color when turned on f
or the
first time
.
This ma
y r
equir
e se
v
eral hours of operation,with more than one
star
t.
Lamp color is also subject to change under conditions of excess vibration
or shock,
and color a
ppearance ma
y var
y betw
een individual lamps.
8) Lamps may require 10–20 minutes to re-light if there is a power interruption.
9)
T
ak
e car
e in handling and disposing of lamps.
If an ar
c tube is br
oken,avoid skin
contact with an
y of the contents or fragments.
MasterColor
®
Metal Halide 250 Watt HPS-Retro White
Horizontal Lamp
R
Lamp Watts (Nominal). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Lamp Operating Voltage (rms) (Nominal)
5
. . . . . . . . . . . . 100
Initial Lamp Voltage Range (rms)
6
. . . . . . . . . . . . . . . . . . . . 90–120
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 3.0
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . 1.8
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . . . 2 Minutes
Restrike Time for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . . 15 Minutes (Average)
Ballast Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI S50
Ballast Open Circuit Voltage (Minimum). . . . . . . . . . . . . . . 198 RMS Min.
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 Minimum, 4000 Maximum
Pulse Width @ 90% Peak . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Micro Second Minimum
Pulse Repetition Rate (Minimum) . . . . . . . . . . . . . . . . . . . . 1 per Half Cycle
M
inimum Operating Temperature . . . . . . . . . . . . . . . . . . . . -30ºC
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
U
pdated 9/05 TDS-146498
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
A
Division of Philips Electronics Ltd.
www.philips.com