Electrical Data (Subject to change without notice)
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Lamp Operating Voltage (rms) (Nominal)
(4)
. . . . . . . . . . 88
Initial Lamp Voltage Range (rms)
(5)
. . . . . . . . . . . . . . . . . 75–100
Lamp Operating Current (Amps) (rms) (Nominal). . . . 0.83
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . 2 Minutes
Re-strike Time for Hot Lamp . . . . . . . . . . . . . . . . . . . . . 4–8 Minutes
Ballast Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M139/O
Ballast Open Circuit Voltage (Minimum) . . . . . . . . . . . . 198
Pulse Peak Volts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min.,4000 Max.
Pulse Width @ 90% Peak . . . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Minimum
Pulse Repetition Rate (Minimum). . . . . . . . . . . . . . . . . . 2 per Half Cycle
Minimum Operating Temperature. . . . . . . . . . . . . . . . . . -30ºC
MasterColor
®
Ceramic Metal Halide 70 Watt PAR30L Spot 4K Lamp with FadeBlock
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Updated 04/06 TDS-151423
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
1) Measured at 100 hrs.life.Approximate lumen values listed are for vertical operation of the lamp.
2) Approximate lumen output at 40% of lamp rated average life.
3) Rated average life is the life obtained,on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more
operating hours per start.It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
4) Measured at rated lamp watts on a linear reactor.LPW does not include ballast losses.
5) Measured with the lamp operating at rated watts.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS
R
“WARNING: These lamps can cause serious skin burn and eye
inflammation from short wave ultraviolet radiation if outer envelope of the lamp
is broken or punctured. Do not use where people will remain for more than a few
minutes unless adequate shielding or other safety precautions are used. Certain lamps
that will automatically extinguish when the outer envelope is broken or punctured are
commercially available.”This lamp complies with FDA radiation performance standard
21 CFR subchapter J. (USA:21CFR 1040.30 Canada: SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at once and replace the
lamp to avoid possible injury from hazardous short wave ultraviolet radiation.
Do not scratch the outer bulb or subject it to pressure as this could cause the
outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause
glass to fly if the envelope is struck.
WARNING: The arc-tube of metal halide lamps are designed to operate under high
pressure and at temperatures up to 1000º C and can unexpectedly rupture due to
internal or external factors such as a ballast failure or misapplication.
If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely
hot glass might be discharged into the surrounding environment.If such
a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY,
PROPERTY DAMAGE,BURNS AND FIRE.These lamps are designed
to retain all the glass particles should an arc tube rupture occur.The following
operating instructions are recommended to minimize
these occurrences.
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing
lamps to operate until they fail is not advised and may increase the possibility
of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing less than 10 nCi of
Kr-85 and is distributed by Philips Lighting Company,a division of Philips
Electronics North America Corporation,Somerset, New Jersey,08875.
CAUTION:TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY
DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE
FOLLOWING LAMP OPERA
TING INSTRUCTIONS MUST BE FOLLOWED:
LAMP OPERA
TING INSTRUCTIONS:
1. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing lamps to operate
until they fail is not advised and may increase the possibility of inner arc tube rupture.
2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool
to avoid electrical shock and potential burn hazards.
3. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage
limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
C. Operate Par 20 3000K and Par 30L 3000K lamps only
on thermally protected ballasts
D. Operate Par 20 4000K and Par 30L 4000K lamps only
on thermally protected electr
onic ballasts
4. Periodically inspect the outer envelope. Replace any lamps that show scratches,
cracks or damage.
5. If a lamp bulb support is used, be sure to insulate the support electrically to
avoid possible decomposition of the bulb glass.
6. Protect lamp base, socket and wiring against moisture,corrosive atmospheres
and excessive heat.
7.Time should be allowed for lamps to stabilize in color when turned on for the
first time. This may require several hours of operation, with more than one start.
Lamp color is also subject to change under conditions of excess vibration or shock,
and color appearance may vary between individual lamps.
8.Lamps may require up to 10 minutes (4–8 minutes for CDM-R111) to re-light if there
is a power interruption.
9.Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact
with any of the contents or fragments.
10. For proper installation and removal, lamp should be handled by the sides of the reflector
and not by the aluminum front anti-glare cap.