Philips 157263 Work Light User Manual


 
Ceramalux
®
High Pressure Sodium Non-Cycling 1000 Watt ED-25 (Clear) Lamp featuring ALTO
®
LampTechnology
E
lectrical Data
(
Subject to change without notice)
LampWatts (Nominal). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Lamp OperatingVoltage (rms) (Nominal). . . . . . . . . . . . . . . . . . 275V
Initial LampVoltage Range (rms). . . . . . . . . . . . . . . . . . . . . . . . . . 250–300V
Lamp Operating Current (Amps) (rms) (Nominal). . . . . . . . . . 4.7
Maximum Lamp Starting Current (Amps)(rms). . . . . . . . . . . . . 8.0
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . . . . . . 1.8
Warm-upTime to 80% of Output. . . . . . . . . . . . . . . . . . . . . . . . 7 Minutes
Re-strikeTime for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Minutes
BallastType. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI S52
Ballast Open CircuitVoltage (Minimum): . . . . . . . . . . . . . . . . . . 456Vrms
Pulse PeakVolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2675
PulseWidth @ 90% Peak. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 µs Minimum at 2700Volts
Pulse Frequency (Minimum)
Lag Ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Cycle
Lead Circuit Ballast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Cycle
Minimum OperatingTemperature. . . . . . . . . . . . . . . . . . . . . . . . . -30°C
Reference Ballast Impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77(ohms) minimum at 480V
Maximum LampWatts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Minimum LampWatts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750
MaximumVoltage Increase by Fixture . . . . . . . . . . . . . . . . . . . . . 25V
Footnotes:
1) Measuredat 100 hours of life in vertical and horizontal positions.
2)Approximate meanlumen outputat 40% oflamp rated average life.Measured invertical andhorizontal operating positions.
3
) Ratedaverage life is thelife obtained,onthe average,from large representative groupsof lamps in laboratory testsunder controlled conditions at10 or more operating hours per start.
I
t isbased on survival of atleast 65%of the lampsand allowsfor individual lamps orgroups of lampsto vary considerably fromthe average.
*TheTCLPis the US EPA’sToxicity Characteristic Leaching Procedure.
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
A
Division of Philips Electronics NorthAmerica Corporation
U
pdated 1/07 TDS-157263
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
WARNINGS,CAUTIONSAND OPERATING INSTRUCTIONS
for Ceramalux High Pressure Sodium Lamps
R
“WARNING:These lamps must be operated in fixtures designed for use with
High Pressure Sodium lamps.The fixture wattage rating must match the wattage
indicated on the outer glass bulb.Do not scratch the outer bulb or subject it to pressure
as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb
may cause glass to fly if the glass is struck.Operating the lamp improperly may result in
PERSONAL INJURY,PROPERTY DAMAGE,BURNSAND FIRE.
1) If the outer glass bulb is broken,shut off power immediately and remove the lamp
after it has cooled.
2) Use only auxiliary equipment meeting Philips and/orANSI standards.Use within
voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
3) Protect lamp base,socket and wiring against moisture, corrosive atmospheres and
excessive heat.
4) Replace the lamp if the outer glass bulb has been scratched,cracked or damaged
in any way.
5) If a lamp bulb support is used,be sure to insulate the support electrically so as to
avoid possible decomposition of the bulb glass.
6) Do not use this lamp in a fixture which redirects a substantial portion of the
energy toward the arc tube and its immediate vicinity,as this may lead to very
early lamp failure.
7) Take care in handling and disposing of lamps.If arc tube is broken,avoid skin
contact with any of the contents or fragments.
8) The arc tube of this lamp contains sodium and mercury.Dispose of in accordance
with federal,state and local requirements.