“WARNING:These lamps can cause serious skin burn and eye inflammation from
short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured.
Do not use where people will remain for more than a few minutes unless adequate
shielding or other safety precautions are used. Certain lamps that will automatically
extinguish when the outer envelope is broken or punctured are commercially
available.” This lamp complies with FDA radiation performance standard 21 CFR
subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured,turn off at once and replace
the lamp to avoid possible injury from hazardous shortwave ultraviolet
radiation.Do not scratch the outer bulb or subject it to pressure as this
could cause the outer bulb to crack or shatter.A partial vacuum in the
outer bulb may cause glass to fly if the envelope is struck.
WARNING:The arc-tube of a metal halide lamp is designed to operate under high
pressure and at temperatures up to 1000º C and can unexpectedly rupture due to
internal or external factors such as a ballast failure or misapplication. If the arc-tube
ruptures for any reason,the outer bulb may break and pieces of extremely hot glass
might be discharged into the surrounding environment. If such a rupture were to
happen,THERE ISA RISK OF PERSONAL INJURY,PROPERTY DAMAGE,
BURNSAND FIRE.
Certain lamps that will retain all the glass particles should inner arc-tube
rupture occur are commercially available from Philips Lighting Company.
RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE.
Allowing lamps to operate until they fail is not advised and may increase
the possibility of inner arc tube rupture.
CAUTION: TO REDUCETHE RISK OF PERSONAL INJURY,PROPERTY
DAMAGE,BURNSAND FIRE RESULTING FROMANARC-TUBE RUPTURETHE
FOLLOWING LAMP OPERATING INSTRUCTIONS
MUST BE FOLLOWED.
Lamp Operating Instructions:
1) Turn off lamps at least once a week for at least 15 minutes in systems which are
operating on a continuous basis (24 hours/day-7days/week).FAILURETOTURN
OFF LAMPS FORTHE MINIMUM RECOMMENDEDTIME MAY INCREASETHE
POSSIBILITY OF AN INNERARC-TUBE RUPTURE.
2) RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE. Allowing lamps
to operate until they fail is not advised and may increase the possibility of inner
arc tube rupture.
3) Before lamp installation/replacement,shut power off and allow lamp and fixture to
cool to avoid electrical shock and potential burn hazards.
4) Use only auxiliary equipment meeting Philips and/orANSI standards.Use within
voltage Limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
C. All Pulse Start mogul based lamps require a socket rated to withstand a
4000 volt pulse.
5) Periodically inspect the outer envelope.Replace any lamps that show scratches,
cracks or damage.
6) If a lamp bulb support is used,be sure to insulate the support electrically to avoid
possible decomposition of the bulb glass.
7) Protect lamp base, socket and wiring against moisture,corrosive atmospheres and
excessive heat.
8) Time should be allowed for lamps to stabilize in color when turned on for the
first time.This may require several hours of operation, with more than one start.
Lamp color is also subject to change under conditions of excess vibration or
shock,and color appearance may vary between individual lamps.
9) Lamps may require up to 10-20 minutes to re-light if there is a power interruption.
10)Take care in handling and disposing of lamps.If an arc tube is broken,avoid skin
contact with any of the contents or fragments.
11)Use this lamp only in fixtures that contain a Pulse Start metal halide ballast and
are specifically designed for use with Pulse Start metal halide lamps.
Protected Pulse Start Metal Halide 750 Watt Lamp (Clear) Technical Data Sheet
Electrical Data (
Subject to change without notice)
LampWatts (Nominal). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750
Lamp OperatingVoltage (rms) (Nominal) . . . . . . . . . . . . . 200
Initial LampVoltage Range (rms) . . . . . . . . . . . . . . . . . . . . . 180-220
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 4.0
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . 1.8
Warm-upTime to 90% of Output . . . . . . . . . . . . . . . . . . . <3 Minutes
Re-strikeTime for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . <10 Minutes
BallastType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M149/O
Ballast Open CircuitVoltage (Minimum). . . . . . . . . . . . . . . 300 RMS Min.
Pulse PeakVolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min.,4000 Max.
PulseWidth @ 2700Volts (micro sec) . . . . . . . . . . . . . . . . 2.2
Pulse Repetition Rate (Minimum) . . . . . . . . . . . . . . . . . . . . 1x / 1/2cycle
Minimum OperatingTemperature . . . . . . . . . . . . . . . . . . . . -30ºC (-22º F)
AdvanceTransformer Ballast Number . . . . . . . . . . . . . . . . 71A64E2
R
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
A
Division of Philips Electronics North America Corporation
U
pdated 8/07 TDS-207571
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com