Philips Ballasts For Fluorescent Lamps Work Light User Manual


 
* data subject to change
Energy saving calculation
Step 1 Determine traditional ‘TL’D 36W, 45W System power
electromagnetic system
(
T8+ballast+starter
)
Step 2 Determine new ‘TL’D 36W, 36W System power
electronic system
(
T8+EB-S ballast
)
Step 3 Determine average 4,000 hours
burning hours per year
(
Typical office building
)
Step 4 Determine cost US$0.10
per KWH
(
Depending on local
supply condition
)
Annual cost saving =
(
Step 1 - Step 2
)
x Step 3 x Step 4
1000
Example:
Annual cost saving =
(
45
-
36
)
x 4000 x US$0.10
*
= US$3.60
1000 Savings per lamp
Product portfolio
Lamp Quantity of lamps
family Wattage on one ballast
18W, 36W, 58W 1, 2, 3 or 4 lamps
PL-L 18W, 36W, 58W 1 or 2 lamps
‘TL’D
Without compromising comfort,the
EB
-
STANDARD
range of
electronic ballasts optimised energy use and extends lamp
and ballast lifetimes.
Philips
EB
-
STANDARD
electronic ballasts start rapidly and operate
without noise or flicker,making life better for everyone whose
life they illuminate.
EB
-
STANDARD
ballasts also lighten the bottom
line: they use only 80% of the energy of traditional ballasts and,
by preheating lamp filaments, give longer lamp life.
The
EB
-
STANDARD
is designed to meet the diverse requirements
of projects and the various regional standards in Asia Pacific.
It does this by complying with demanding international safety and
performance standards,including compliance with the
IEC
928
safety standard and
IEC
929 performance standard.The versatile
EB
-
STANDARD
range works with an extensive combination of
different lamp wattages.
The manufacture of the
EB
-
STANDARD
in an
ISO
9001
environment further guarantees the reliability of the electronic
ballast.
ISO
14001 certification gives customers the peace of mind
that comes from knowing the products they use are manufactured
in an environmentally responsible way. Long lamp life and long
ballast lifetimes make the
EB
-
STANDARD
ideal for situations with
frequent switches per day or where demands on the ballast are
heavy.The
EB
-
STANDARD
is built to meet the varied requirements
of projects and regional standards across the Asia-Pacific region.
Benefits
DESIGNED BY PHILIPS DESIGN HONG KONG
2002
In the Asia Pacific region mains voltage fluctuation can be a daily occurrence affecting the
output of fluorescent lamps and impeding ignition. The
EB-STANDARD
range of electronic
ballasts gives you back control over lighting conditions. The range is designed to suit
the spectrum of rated mains voltages in the region from 220-240V, 50 and/or 60Hz
and to handle mains voltage fluctuations from 216-247V without affecting performance.
Additionally, the lamps will continue to operate well even if mains voltage drops to 184V
or rises to 264V.