Philips CDM-i25w Work Light User Manual


 
CDM-i25w/PAR38/ALTO
Philips MasterColor
®
Integrated 25W PAR38 Ceramic Metal Halide Lamps
featuring ALTO
®
Lamp Technology
Ordering Data
P
roduct Pkg.
N
umber Ordering Code Qty. Beam MBCP
2
1
4477-4 CDM-i25W/830/PAR38/10/ALTO 6 Spot (10˚) 26,000
1
4478-2 CDM-i25W/830/PAR38/25/ALTO 6 Flood (25˚) 5600
1
4479-0 CDM-i25W/830/PAR38/40/ALTO 6 Wide Flood (40˚) 2100
W
arnings,Cautions and Operating Instructions
WARNING:These lamps can cause serious skin burn
a
nd eye inflammation from short wave ultraviolet radiation
if outer envelope of the lamp is broken or punctured.Do
n
ot use where people will remain for more than a few
m
inutes unless adequateshielding orother safety precautions
are used.Certain lamps that will automatically extinguish
w
henthe outer envelope is broken or punctured are
commerciallyavailable.”This lamp complies withFDA
r
adiation performance standard 21 CFR subchapter J.
(USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
I
f the outer bulb is broken or punctured,turn off at
o
nce and replace the lamp to avoid possible injury
from hazardous short wave ultraviolet radiation.Do
n
ot scratch the outer bulb or subject it to pressure
as this could cause the outer bulb to crack or shatter.
A
partial vacuum in the outer bulb may cause glass
to fly if the envelope is struck.
WARNING:Thearc-tube of metal halide lampsaredesigned
t
o operate under high pressure and at temperatures up to
1000°C and can unexpectedly rupture due to internal or
e
xternal factors such as a ballast failure or misapplication.
If the arc-tube ruptures for any reason,the outer bulb may
b
reak and pieces of extremely hot glass might be discharged
into the surrounding environment.If such a rupture were to
happen,THERE ISA RISK OF PERSONAL INJURY,
PROPERTY DAMAGE,BURNSAND FIRE.
T
his lamp contains an arc tube with a filling gas
containing less than 41 nCi of Kr-85 and is distributed
b
y Philips Lighting Company,a division of Philips
Electronics NorthAmerica Corporation,Somerset,
New Jersey,08875.
CAUTION:TO REDUCETHE RISKOF PERSONALINJURY,
PROPERTY DAMAGE,BURNSAND FIRE RESULTING
FROMANARC-TUBE RUPTURETHE FOLLOWING
LAMPOPERATING INSTRUCTIONS
MUSTBEFOLLOWED.
LAMP OPERATING INSTRUCTIONS:
1.At high lighting levels or when illuminating light-sensitive
materials the use of an extra UV filter is recommended.
2.Before lamp installation/replacement,shut power off and
allow lamp and fixture to cool to avoid electrical shock and
potential burn hazards.
3.Time should be allowed for lamps to stabilize in color
when turned on for the first time.This may require several
hours of operation,with more than one start.Lamp color
is also subject to change under conditions of excess
vibration or shock,and color appearance may vary
between individual lamps.
4.Lamps may require up to 10 minutes to re-light if there
is a power interruption.
5.Do not operate with an additional ballast,since a ballast
is integrated in the lamp itself.
6.Do not use in totally enclosed recessed fixtures.
7.Take care in handling and disposing of lamps.If an
arc tube is broken,avoid skin contact with any of the
contents or fragments.
8.Lamp should not be used with dimmers.
9.Protect lamp,lamp socket and wiring against moisture,
corrosive atmosphere and excessive heat.Lamp should
be used in dry locations only.
These lamps may be used in open fixtures.
Hg:LAMP CONTAINS MERCURY Manage
inAccord with Disposal Laws See:
www.lamprecycle.org or 1-800-555-0050
1) Rated average life is the life obtained,on the average,from large representative groups of lamps in laboratorytests
under controlled conditions at 10 or more operating hours per start.It is based on survival of at least 50% of the
lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
2) Maximum Beam Candlepower.
3) CAUTION:New construction should allow for the current used by these lamps.Because of a power factor
of 0.57 in the ballast of the lamp,the lamp uses .36 amps.
4) Measured at 100 hrs.life.Approximate lumen values listed are for vertical operation of the lamp.
5)Approximate lumen output at 40% of lamp rated average life.
This product utilizesALTO
®
LampTechnology.ALTO products pass the US EPA'sToxicity Characteristic Leaching
Procedure (TCLP) and can be classified as non-hazardous waste. Check with state and local regulations.
Above specifications subject to change without notice.
© 2008 Philips Lighting Company.All rights reserved.
Printed in USA 12/08
P-5747-F
www.philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
A Division ofPhilipsElectronics NorthAmerica Corporation
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
A Division ofPhilipsElectronics Ltd.
Electrical andTechnical Data
W
attage ––––––––––––––––––––––––––––––––25W
I
nputVoltage ––––––––––––––––––––––––120V±10%
M
ax.THD–––––––––––––––––––––––––––––––142%
F
requency–––––––––––––––––––––––––––––––60Hz
I
nput Current
3
–––––––––––––––––––––––––––0.36
W
arm-up to 80% Full Brightness –––––––––2 minutes
R
estrikeTime for Hot Lamps–––––––––– 5-7 minutes
M
inimum OperatingTemp.–––––––––––– -20˚C (-4˚F)
Physical Characteristics
B
ulb Size–––––––––––––––––––––––––––––––PAR38
B
ulb Finish ––––––––––––––––––––––––––––––Clear
B
ase –––––––––––––––––––––––––––––––––Medium
M
ax.Overall Length (MOL)–––––––––5.33'' (135mm)
L
ight Center Length (LCL) ––––––––––––––––––N/A
A
rc Length–––––––––––––––––––––––––––––––N/A
A
rcTube Material ––––––––––PolycrystallineAlumina
M
ax.RingTemp.––––––––––––––––––––65ºC (149ºF)
M
ax.CapTemp. ––––––––––––––––––––65ºC (149ºF)
M
ax.NeckTemp. –––––––––––––––––––80˚C (176˚F)
M
ax.ArcTube to Base Eccentricity––––––––––––––3º
Operating Characteristics
Approx.Initial Lumens
4
–––––––––––––––––––––1275
Approx.Mean Lumens
4
,5
–––––––––––––––––––––880
RatedAverage Life,Hours.
1
––––––––––––––––15,000
Correlated ColorTemp.(CCT)
2
––––––––––––3000K
CIE ChromaticityApprox.
2
–––––––––––x-.440,y-.393
Color Rendering Index (CRI)––––––––––––––––––87
Efficacy (lpw)–––––––––––––––––––––––––––––––51
BeamAngle (at 50% of MBCP)––––––––––10˚/25˚/40˚
Operating Position
Universal-Open or Enclosed PAR Style Luminaires
(Do not use in totally enclosed recessed luminaires.)
Spectral Power Distribution
Power (W per nm)
200 300 400 500 600 700 800
W
avelength (Nanometers)
0.08
0.07
0.06
0.05
0
.04
0.03
0.02
0.01
0