Philips P-2055-D Work Light User Manual


 
PhilipsWhite SON
®
Lamps
© 2007 Philips Lighting Company.All rights reserved.
Printed in USA 06/07
P-2055-D
www.philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
ADivision ofPhilips ElectronicsNorthAmerica Corporation
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
ADivision ofPhilips ElectronicsLtd.
Abovespecifications subject tochange without notice.
Printed onchlorine freepaper fromSappi FinePaper mills,who areaccredited withEMAS environmental certification.
Sappi claims that the pulp usedin the manufacture of Magno Dullpaper isderived from environmentally certifiedforests.
Electrical and Technical Data
Lamp Current Crest Factor (Maximum) ————1.8
Warm-up to 80% Full Brightness ———3–4 minutes
RestrikeTime for Hot Lamps ———— 1–2 minutes
Starter PulseVoltage—Peak ——————3500-4900
PulseWidth @ 90% Peak —0.5 Micro Sec.Minimum
Pulse per Cycle (Minimum) ——————————1
Physical Characteristics
Bulb ——————————————ED-17 (SDW)
———————————————T-10 (SDW-T)
B
ulb Finish ———————————Diffuse (SDW)
——————————————— Clear (SDW-T)
Base —————————————Medium (SDW)
———————————————PG-12 (SDW-T)
Max.Overall Length (MOL) —5.438'' (xxmm) (SDW)
———————————5.875" (XXmm) (SDW-T)
Light Center Length (LCL) —3.438'' (xxmm) (SDW)
———————————3.563" (XXmm) (SDW-T)
Arc Length —————————0.X'' (7mm) (50W)
———————————— 0.XX" (9mm) (100W)
Max.BulbTemp.————350ºC (XXXºF) (50WT-10)
————— 400˚C (XXX˚F) (50W & 100W ED-17)
————————— 450˚C (XXX˚F) (100WT-10)
Max.BaseTemp. ———————150°C (50WT-10)
—————————190°C (50W & 100W ED-17)
—————————————180°C (100WT-10)
Standard Package Quantity ————————— 12
Operating Characteristics
RatedAverage Life,Hours.
3,4
———————10,000
Color Rendering Index (CRI)—————————85
ColorTemperature ———————————2700K
Operating Position
U
niversal
Ordering Data
Lamp
Oper. Approx. Approx
Product Lamp Lamp Current ANSI Initial Mean
Number Ordering Code Watts Volts (Amps) Code Lumens
1
Lumens
2
31344-5 SDW-50W/LV/D 50 45 1.4 S104 2350 2000
3
1346-0 SDW-100W/LV/D 100 52 2.5 S105 4900 4170
3
0229-9 SDW-T50W/LV 50 45 1.4 S104AF-50 2300 2070
3
0228-1 SDW-T100W/LV 100 52 2.5 S105NZ-100 5000 4250
WHITE SON
®
R
ECOMMENDEDWARNINGS,CAUTIONSAND
O
PERATING INSTRUCTIONS
R
WARNING:
T
hese lamps must be operatedin fixtures
d
esigned for use with HighPressure Sodium lamps.The
xture wattage ratingmust match the wattage indicated on the
o
uter glass bulb.Donot scratch the outer bulb or subject it to
pressure as this could cause the outer bulb to crack or shatter.
A partial vacuum in the outer bulb may cause glass to fly if the
glass is struck.Operating the lamp improperly mayresult in
PERSONAL INJURY,PROPERTY DAMAGE,BURNSAND FIRE.
1.If the outer glass bulb is broken,shut off power immediately
and remove the lamp after it has cooled.
2.Useonly auxiliary equipment meeting Philips and/orANSI
s
tandards.Use within voltage limitsrecommended by
b
allast manufacturer.
A
.Operate lamp only within specified limits of operation.
B
.For total supply load refer to ballast manufacturers
e
lectrical data.
3
.Protect lamp base,socket and wiring against moisture,
corrosive atmospheres andexcessive heat.
4.Replacethe lamp if the outer glass bulb has been scratched,
cracked ordamaged in any way.
5.If alamp bulb support is used,besure to insulate the support
electrically so as to avoidpossible decomposition of the
bulb glass.
6.Do notuse this lamp in a fixture which redirects a substantial
portion of the energy toward the arc tube and its immediate
v
icinity,as this may lead to very early lamp failure.
7.Takecare inhandlinganddisposingoflamps.Ifarc tube isbroken,
avoid skin contact with any of the contents or fragments.
8.The arc tube of this lamp contains sodium and mercury.
Dispose of lamp in accordance with federal,state and
local requirements.
C.I.E.Color Coordinates X Y
50Watt .462 .414
100Watt .461 .410
Maximum Color Shift:
-250K (7500 hours)
1
) Basedon photometry of100-hour lampsin vertical positionat rated watts. Lumenoutput rating appliesto alloperating positions.
2
) Lumenoutput at50% rated life.
3
) Basedon survival of atleast 50%of thelamps,operated underspecified test.
4
) 90%survivalat 5000hours.