Philips P-2257-D Work Light User Manual


 
1) Rated average life is thelife obtained,on the average,from large representative groups of lamps in laboratory tests under controlled conditionsat 10 or more operating hours per start.It isbased on survival of at least 67%
of the lamps and allows for individuallamps or groups of lamps to vary considerably from theaverage.
2) Measured at 100 hrs.life.Approximate lumenvalues listed are for vertical and horizontal operation of the lamp.
3)Approximate lumen output at40% of lamp rated average life.
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics NorthAmerica Corporation
Printed in USA 2/07 P-2257-D
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
Ceramalux
®
Instant Restrike High Pressure Sodium Lamps
Electrical,Technical and Ordering Data (Subject to change without notice)
Std. Rated Approx. Approx. .
Product Ordering ANSI Operating Bulb Pkg. LCL MOL Avg.Life Initial Mean CCT
Number Code Code Watts Bulb Base Position Finish Qty. (In.) (In.) (Hrs)
1
Lumens
2
Lumens
3
CRI (K)
35467-0 C50S68/2 S68 50 ED23
1
2
Mogul Universal Clear 12 57
3
4
24,000+ 3800 3450 21 2100
26541-3 C70S62/2 S62 70 ED23
1
2
Mogul Universal Clear 12 57
3
4
24,000+ 5600 5050 21 2100
26560-3 C100S54/2 S54 100 ED23
1
2
Mogul Universal Clear 12 57
3
4
24,000+ 9100 8190 21 2100
26561-1 C150S55/2 S55 150 ED23
1
2
Mogul Universal Clear 12 57
3
4
24,000+ 15,600 14,000 21 2100
37717-6 C250S50/2 S50 250 ED18 Mogul Universal Clear 12 5
3
4
9
3
4
24,000+ 27,500 24,750 21 2100
37688-9 C400S51/2 S51 400 ED18 Mogul Universal Clear 12 5
3
4
9
3
4
24,000+ 49,000 44,000 21 2100
20412-3 C1000S52/2 S52 1000 E-25 Mogul Universal Clear 6 8
3
4
15
1
16
24,000+ 140,000 126,000 21 2100
Warnings,Cautions and Operating Instructions
WARNING: These lamps must be operated in fixtures
designed for use with High Pressure Sodium lamps.
The fixture wattage rating must match the wattage indicated
on the outer glass bulb.Do not scratch the outer bulb or
subject it to pressure as this could cause the outer bulb to
crack or shatter.A partial vacuum in the outer bulb may
cause glass to fly if the glass is struck.Operating the lamp
improperly may result in PERSONAL INJURY,
PROPERTY DAMAGE,BURNSAND FIRE.
1.If the outer glass bulb is broken,shut off power immediately
and remove the lamp after it has cooled.
2.Use only auxiliary equipment meeting Philips and/orANSI
standards.Use within voltage limits recommended by ballast
manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers
electrical data.
3.Protect lamp base,socket and wiring against moisture,
corrosive atmospheres and excessive heat.
4.Replace the lamp if the outer glass bulb has been scratched,
cracked or damaged in any way.
5.If a lamp bulb support is used,be sure to insulate the sup-
port electrically so as to avoid possible decomposition of
the bulb glass.
6.Do not use this lamp in a fixture which redirects a
substantial portion of the energy toward the arc tube
and its immediate vicinity, as this may lead to very
early lamp failure.
7.Take care in handling and disposing of lamps.If arc tube
is broken,avoid skin contact with any of the contents
or fragments.
8.The arc tube of this lamp contains sodium and
mercury. Dispose of in accordance with federal,
state and local requirements.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for
Ceramalux
®
High Pressure Sodium Lamps