Philips T5 Work Light User Manual


 
Average Rated
Std. Color Color Nominal Average Approx.
Product Nominal Pkg. Temp. Rendering Length Life Initial Design
Number Description Watts Bulb Base Qty. (Kelvin) (CRI) (in) (hrs)
1
Lumens
2,3
Lumens
4
23077-1 F14T5/830/ALTO 14 T5 Min. Bipin 40 3000K 85 22 20,000 1350 1275
23079-7 F14T5/835/ALTO 14 T5 Min. Bipin 40 3500K 85 22 20,000 1350 1275
23080-5 F14T5/841/ALTO 14 T5 Min. Bipin 40 4100K 85 22 20,000 1350 1275
23081-3 F21T5/830/ALTO 21 T5 Min. Bipin 40 3000K 85 34 20,000 2100 2000
23082-1 F21T5/835/ALTO 21 T5 Min. Bipin 40 3500K 85 34 20,000 2100 2000
23083-9 F21T5/841/ALTO 21 T5 Min. Bipin 40 4100K 85 34 20,000 2100 2000
23084-7 F28T5/830/ALTO 28 T5 Min. Bipin 40 3000K 85 46 20,000 2900 2750
23085-4 F28T5/835/ALTO 28 T5 Min. Bipin 40 3500K 85 46 20,000 2900 2750
23086-2 F28T5/841/ALTO 28 T5 Min. Bipin 40 4100K 85 46 20,000 2900 2750
23088-8 F35T5/830 35 T5 Min. Bipin 40 3000K 85 58 20,000 3650 3450
23091-2 F35T5/835 35 T5 Min. Bipin 40 3500K 85 58 20,000 3650 3450
23095-3 F35T5/841 35 T5 Min. Bipin 40 4100K 85 58 20,000 3650 3450
1) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours.Lamp life is appreciably longer if lamps are started less frequently,
2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life,when the output is measured during operation on a reference ballast under standard laboratory conditions.
3) For expected lamp lumen output,commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier
applied to the designated lamp lumen output.
4) Design lumens are the approximate lamp lumen output at 40%of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.
SILHOUETTE
T5 Fluorescent Lamps featuring ALTO
®
Lamp Technology
Electrical,Technical and Ordering Data (Subject to change without notice)
A
MAX. O.D.
17.0 mm
.67 in.
B
C
Lamp Dimensions
inches mm inches mm inches mm inches mm
F14T5 21.61 549.0 21.80 553.7 21.89 556.1 22.17 563.2
F21T5 33.42 849.0 33.61 853.7 33.70 856.1 33.98 863.2
F28T5 45.24 1149.0 45.42 1153.7 45.52 1156.1 45.80 1163.2
F35T5 57.05 1449.0 57.23 1453.7 57.33 1456.1 57.61 1463.2
AB BC
MAX. MIN. MAX. MAX.
Lamp
Type
Spectral Power Distribution
400
450
500 600550 650
700
100
80
60
40
20
0
Relative Energy
Wavelength (Nanometers)
Spectral Power Distribution – TL830
400
450
500 600550 650
700
100
80
60
40
20
0
Relative Energy
Wavelength (Nanometers)
Spectral Power Distribution – TL835
400
450
500 600550 650
700
100
80
60
40
20
0
Relative Energy
Wavelength (Nanometers)
Spectral Power Distribution – TL841
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Printed in the USA 12/05 P-5123-D
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
Silhouette
T5 Lumens vs. Ambient Temperature
Lumen Output (%)
Ambient Temperature (°C)
10
15
20
25
30
35
40
45
50
55
5
10
20
30
40
50
60
70
80
90
100
110
0
T5
T8
102
100
98
96
94
92
90
0
5000 10000 15000 20000 25000 30000
Light Output (%)
Lamp Operating Hours
Energy Lumen Maintenance
T5/HO — 2004