Philips Metal Halide 360 Watt Econ-o-watt
®
Ordering, Electrical andTechnical Data
Rated Approx. Approx.
Product Ordering ANSI Pkg. LCL MOL Avg.Life Initial Mean CCT
Number Code Code Watts Bulb Base Qty. (In.) (In.) (Hrs.)
1
Lumens
2
Lumens
3
CRI (Kelvin)
4
39065-8 MS360/BU/EW M165/M59/S 360 ED-37 Mog. 6 7.0 11.5 20,000 36,000 24,500 60 4300
39066-6 MS360/C/BU/EW M165/M59/S 360 ED-37 Mog. 6—11.5 20,000 34,200 22,600 65 4000
1) Rated average life is the life obtained,on the average,from large representativegroups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start.
It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerablyfrom the average.
2)Approximatelumen values listed are for vertical operation of the lamp.
3)Approximatelumen output at 40% of lamp ratedaverage life.
4)Approximate colortemperaturein Kelvin degrees.
Abovespecifications are subject to change without notice.
© 2008 Philips Lighting Company.All rights reserved.
Printed in USA 4/08
P-5561-D
www.philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
ADivisionof PhilipsElectronicsNorthAmericaCorporation
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
ADivisionof PhilipsElectronicsLtd.
WARNINGS,CAUTIONSANDOPERATING INSTRUCTIONS FOR
STANDARDMETALHALIDE LAMPS (ENCLOSED FIXTURES ONLY
UNLESSOTHERWISENOTED)
R
WARNING:
Theselampscancauseseriousskin burnandeyeinflammationfromshortwave
ultravioletradiationifouterenvelopeofthelampisbrokenorpunctured.Donotusewherepeople
willremainformorethana fewminutesunlessadequateshieldingorothersafetyprecautionsareused.
Certainlampsthatwillautomaticallyextinguishwhentheouterenvelopeisbrokenorpuncturedare
commerciallyavailable.”ThislampcomplieswithFDAradiationperformancestandard21CFRsubchapter
J.(USA:21CFR1040.30Canada:SOR/DORS/80-381)
Iftheouterbulbisbrokenorpunctured,turnoffatonceandreplacethelamptoavoid
possibleinjuryfromhazardousshortwaveultravioletradiation.Donotscratchtheouter
bulbor subjectitto pressureas thiscouldcausetheouterbulbtocrackor shatter.A
partialvacuumintheouterbulbmaycauseglasstoflyif theenvelopeisstruck.
WARNING:Thearc-tubeofmetalhalidelampsaredesignedto operateunderhighpressureandat
temperaturesup to1000ºC andcanunexpectedlyruptureduetointernalor externalfactorssuchasa
ballastfailureormisapplication.Ifthearc-tuberupturesforanyreason,theouterbulbmaybreakand
piecesofextremelyhotglassmightbedischargedintothesurroundingenvironment.Ifsucharupture
weretohappen,THEREISA RISKOF PERSONALINJURY,PROPERTYDAMAGE,BURNS
ANDFIRE.
Certainlampsthatwillretainalltheglassparticlesshouldinnerarc-tuberuptureoccur
arecommerciallyavailablefromPhilipsLightingCompany.
RELAMPFIXTURESATORBEFORETHEENDOF RATEDLIFE.Allowinglampsto
operateuntiltheyfailisnotadvisedandmayincreasethepossibilityofinnerarc
tuberupture.
CAUTION:TOREDUCETHERISKOFPERSONALINJURY,PROPERTYDAMAGE,BURNSAND
FIRERESULTINGFROMANARC-TUBERUPTURETHEFOLLOWINGLAMPOPERATING
INSTRUCTIONSMUSTBEFOLLOWED:
LAMPOPERATINGINSTRUCTIONS:
1.Turnofflampsatleastonceaweekforatleast15minutesinsystemswhichareoperatingonacontinuous
basis (24 hours/day-7days/week).FAILURETOTURN OFF LAMPS FORTHE MINIMUM
RECOMMENDEDTIMEMAYINCREASETHEPOSSIBILITYOFANINNERARC-TUBERUPTURE.
2.RELAMPFIXTURESATORBEFORETHEENDOF RATEDLIFE.Allowinglampsto operateuntilthey
failis notadvisedandmayincreasethepossibilityofinnerarctuberupture.
3.Useonlyinanenclosedfixturecapableofwithstandingparticlesofglasshavingtemperaturesupto1000ºC.
4.Beforelampinstallation/replacement,shutpoweroffandallowlampandfixtureto coolto avoid
electricalshockandpotentialburnhazards.
5.UseonlyauxiliaryequipmentmeetingPhilipsand/orANSIstandards.Usewithinvoltagelimits
recommendedbyballastmanufacturer.
A.Operatelamponlywithinspecified limits of operation.
B.For total supply load refer to ballast manufacturers electrical data.
6.Periodically inspect the outer envelope.Replace any lamps that show scratches,cracks or damage.
7.Ifa lamp bulb support is used,be sure to insulate the support electrically to avoidpossible
decomposition of the bulb glass.
8.Protectlamp base,socket and wiring against moisture,corrosive atmospheres and excessive heat.
9.Timeshould be allowed for lamps to stabilize in color when turned on for the first time.This may
require several hours of operation,withmore than one start.Lampcolor is also subject to change
underconditionsofexcessvibrationorshockandcolorappearancemayvarybetweenindividuallamps.
10.Lampsmay require 10 to 20 minutes to re-light if there is a power interruption.
11.Take care in handling and disposing of lamps.If an arc tube is broken,avoid skin contact with any of
the contents or fragments.
12.Donot use this lamp:
A.Ina fixture that contains a Pulse Start metal halide ballast.
B.In a fixture that is specifically designed for use with Pulse Start metal halide lamps.Operation
of these lamps on Pulse Start Metal Halide systems may increasethe chance of
an outer bulb rupture and pieces of extremely hot glass might be discharged
into the surroundingenvironment.If such a rupture were to happen,THEREISA
RISK OF PERSONAL INJURY,PROPERTY DAMAGE,BURNSANDFIRE.
B
A
Lamp Dimensions
Metal Halide 360W ED-37
A — 4.625"
B — 11.5"
P-5661-D Metal halide 360 Econ_Prod_Bulletin:Layout 1 4/2/08 5:35 PM Page 2