rdering, Electrical and Technical Data
C
olor Nom. RatedAverage Life (hrs)
1
A
pprox.
P
roduct Ordering Pack. Temp. Length 12-hr on 12-hr on Initial Design Lumen
N
umber Code Watts Qty. (Kelvin) (In.) Ins.Start Prog.Start Lumens
2
L
umens
3
C
RI Maint.
15202-5 F32T8/TL830/XLL/ALTO 32 25 3000 48 40,000 46,000 2950 2800 85 95%
15203-3 F32T8/TL835/XLL/ALTO 32 25 3500 48 40,000 46,000 2950 2800 85 95%
1
5204-1 F32T8/TL841/XLL/ALTO 32 25 4100 48 40,000 46,000 2950 2800 85 95%
1
5205-8 F32T8/TL850/XLL/ALTO 32 25 5000 48 40,000 46,000 2850 2700 85 95%
Specifications are subject to change without notice.
© 2007 Philips Lighting Company.All rights reserved.
Printed in USA 06/07
P-5794-B
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O.Box 6800
Somerset,NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics NorthAmerica Corporation
Philips Lighting
281 Hillmount Road
Markham,Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
1
)Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory
c
onditions.For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a
multiplier applied to the designated lamp lumen output.
3) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard
laboratory conditions.
Lamp meets US Federal Minimum Efficiency
Standards.
This lamp is better for the environment because of its reduced mercury content.All Philips ALTO II
lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state
a
nd local regulations.
E
0 10,000 20,000 30,000 40,000 50,000 0 10,000 20,000 30,000 40,000 50,000
Rated Average Life in HoursRated Average Life in Hours
BASED ON 3 HOURS PER START
4
B
ASED ON 12 HOURS PER START
1
Instant Start Ballast Programmed Start Ballast
3
6,000
40,000
4
0,000
46,000
Rated Average Life
Philips T8 32W XLL Lamps
1
00%
9
8%
9
6%
9
4%
92%
90%
1
00%
9
8%
9
6%
9
4%
92%
90%
Lamp Operating HoursLamp Operating Hours
Light Output (%)Light Output (%)
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 45,000 50,000
95% Lumen Maintenance
Philips T8 32W XLL Lamps
E
E
E
E
4) Average life under specified test conditions with lamps turned off
and restarted no more frequently than once every 3 operating hours.
Lamp life is appreciably longer if lamps are started less frequently.
Footnotes from front page:
*When compared to an industry standard 4'T8 32W lamp with 24,000 hours rated average life (12 hours per start on an instant start ballast), with 2800 lumens and 75 CRI.
Printed on chlorine free paper from Sappi Fine Paper mills,who are accredited with EMAS environmental certification.