Philips R111 Work Light User Manual


 
MasterColor
®
Ceramic Metal Halide 38 Watt R111 Reflector Spot Lamp with FadeBlock
Electrical Data (
Subject to change without notice)
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Lamp Operating Voltage (rms) (Nominal)
4
. . . . . . . . . . . . . 88
Initial Lamp Voltage Range (rms)
5
. . . . . . . . . . . . . . . . . . . . . 80-100
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 0.53
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . 1.8
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . . . 3 Minutes
Re-strike Time for Hot Lamp . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Minutes
Ballast Type (Electronic Only). . . . . . . . . . . . . . . . . . . . . . . . ANSI M130/O
Ballast Open CircuitVoltage (Minimum). . . . . . . . . . . . . . . 198
Pulse PeakVolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min.,4000 Max.
Pulse Width @ 90% Peak . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Minimum
Pulse Repetition Rate (Minimum)
6
. . . . . . . . . . . . . . . . . . . . 1 per Half Cycle
Minimum OperatingTemperature . . . . . . . . . . . . . . . . . . . . -30ºC (-22ºF)
1
) Measured at 100 hrs.life.Approximate lumen values listed are for vertical operation of the lamp.
2
) Approximate lumen output at 40% of lamp rated average life.
3) Rated average life is the life obtained,on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50%
of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
4) Measured at rated lamp watts on a linear reactor.LPW does not include ballast losses.
5) Measured with the lamp operating at rated watts.
6
) Option-PulseWidth @ 90% Peak,1 micro second minimum with 2 pulses per half cycle.
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A
Division of Philips Electronics North America Corporation
U
pdated 6/07 TDS-135541
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
Warnings, Cautions and Operating Instructions
R
“WARNING: These lamps can cause serious skin burn and eye inflammation
from short wave ultraviolet radiation if outer envelope of the lamp is broken or
punctured. Do not use where people will remain for more than a few minutes unless
adequate shielding or other safety precautions are used.Certain lamps that will automatically
extinguish when the outer envelope is broken or punctured are commercially available.”
This lamp complies with FDA radiation performance standard 21 CFR subchapter J.
(USA:21CFR 1040.30 Canada: SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at once and replace the lamp
to avoid possible injury from hazardous short wave ultraviolet radiation. Do
not scratch the outer bulb or subject it to pressure as this could cause the
outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause
glass to fly if the envelope is struck.
WARNING: The arc-tube of metal halide lamps are designed to operate under high
pressure and at temperatures up to 1000º C and can unexpectedly rupture due to
internal or external factors such as a ballast failure or misapplication. If the arc-tube
ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might
be discharged into the surrounding environment. If such a rupture were to happen, THERE
IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
These lamps are designed to retain all the glass particles should an arc tube
rupture occur.The following operating instructions are recommended to
minimize these occurrences.
RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE.Allowing
lamps to operate until they fail is not advised and may increase the possibility
of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing less than 10 nCi of
Kr-85 and is distributed by Philips Lighting Company, a division of Philips
Electronics North America Corporation, Somerset, New Jersey, 08875.
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE,
BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING
LAMP OPERATING INSTRUCTIONS
MUST BE FOLLOWED:
LAMP OPERATING INSTRUCTIONS:
1. RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate
until they fail is not advised and may increase the possibility of inner arc tube rupture.
2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool
to avoid electrical shock and potential burn hazards.
3. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage
limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
C.Operate 39W PAR-20 and PAR-30L lamps only on thermally
protected ballast.
D.Operate CDM-R111 lamp only on approved thermally protected
electronic ballast.
4. Periodically inspect the outer envelope. Replace any lamps that show scratches,
cracks or damage.
5. If a lamp bulb support is used, be sure to insulate the support electrically to avoid
possible decomposition of the bulb glass.
6. Protect lamp base, socket and wiring against moisture, corrosive atmospheres
and excessive heat.
7. Time should be allowed for lamps to stabilize in color when turned on for the first time.
This may require several hours of operation, with more than one start. Lamp color is also
subject to change under conditions of excess vibration or shock, and color appearance
may vary between individual lamps.
8.Lamps may require up to 10 minutes (4–8 minutes for CDM-R111) to re-light if there is a
power interruption.
9. Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact
with any of the contents or fragments.
10. For proper installation and removal, lamp should be handled by the sides of the reflector
and not by the aluminum front anti-glare cap.