35
36. SCREEN WIPER Set
Function
The external control equipment sets the SCREEN WIPER of the plasma
monitor.
Transmission Data
DFH 80H 60H C8H 04H DATA00 to DATA03 CKS
DATA00 : SCREEN WIPER 00H : No operation
01H : ON
02H : OFF
DATA01 : WORKING TIME 00H : ON
01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
DATA02 : WAITING TIME 01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
DATA03 : SPEED 01H : 1
:
05H : 5
ACK
3FH 60H 80H C8H 00H CKS
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes.
Example: 03H=9 minutes
1EH=
1 hour and 30 minutes