2. While pressing the arbor lock button, extend the lever on the Quik-
Change blade clamp (A) Fig. 2 and turn it counter-clockwise.
3. Remove the Quik-Change blade clamp, release the arbor lock button,
and remove the outer blade flange.
4. Retract the telescoping guard (A) Fig. 3 and remove the blade.
8
DISCONNECT TOOL FROM POWER SOURCE.
Fig. 2
Fig. 3
Fig. 4
Fig. 5
A
A
A
1. Remove any accumulated sawdust or other contaminates from the
guards, from around the arbor, and from the blade clamp. Check the
telescoping guard to ensure that it is in working order.
2. Clean the inner blade flange, retract the telescoping guard, and place
the new blade on the arbor. Verify that the teeth point up at the front of
the saw (Fig. 4).
3. Place the outer blade flange (A) Fig. 5 on the arbor with the smooth side
against the blade. Mate the flats with those on the arbor.
4. Replace the Quik-Change blade clamp (A) Fig. 2 finger tight by turning it
clockwise. Push in the arbor lock button (A) Fig.1, extend the lever on
the Quik-Change blade clamp (A) Fig. 2, and hand-tighten the assembly
securely. Release the arbor lock.
Avoid contact with the blade teeth to prevent personal
injury.
INSTALLING THE BLADE
NOTE: DO NOT use wet lubricants on the Quik-Change blade clamp.
Verify that the Quick Change blade clamp lever is tight, and
quickly returns to its closed position before connecting the
tool to the power source. If it doesn’t return, clear the
debris from the clamp. Visually inspect the blade clamp