8 - ENG
A02492
GLOSSARY
DUTY CYCLE
Accessories for this unit are available at the store the unit was purchased.
ACCESSORIES
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per
minute; a unit of measure of air
delivery.
PSIG: Pounds per square inch
gauge; a unit of measure of pressure.
Code Certification: Products that
bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent safety laboratories and
meet the applicable Underwriters
Laboratories Standards for Safety.
Cut-In Pressure: While the motor is
off, air tank pressure drops as you
continue to use your accessory.
When the tank pressure drops to a
certain low level the motor will restart
automatically. The low pressure at
which the motor automatically
restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air
compressor is turned on and begins
to run, air pressure in the air tank
begins to build. It builds to a certain
high pressure before the motor
automatically shuts off - protecting
your air tank from pressure higher
than its capacity. The high pressure
at which the motor shuts off is called
"cut-out" pressure.
Branch Circuit: Circuit carrying
electricity from electrical panel to
outlet.
This air compressor pump is capable
of running continuously. However, to
prolong the life of your air
compressor, it is recommended that a
50%-75% average duty cycle be
maintained; that is, the air compressor
pump should not run more than 30-45
minutes in any given hour.
SPECIFICATIONS
Model No. C3001
Horsepower Peak 3.0
Bore 1.875"
Stroke 1.250"
Voltage-Single Phase 120
Minimum Branch Circuit Requirement 15 amps
Fuse Type Time Delay
Air Tank Capacity (Gallon) 4
Approximate Cut-in Pressure 120 PSIG
Approximate Cut-out Pressure 150 PSIG
SCFM @ 40 PSIG 4.9
SCFM @ 90 PSIG 3.5