Porter-Cable C6001 Air Compressor User Manual


 
18 - ENG1000002853
PROBLEM CAUSE CORRECTION
Pressure reading on
the regulated pressure
gauge drops when an
accessory is used.
It is normal for "some"
pressure drop to occur.
If there is an excessive
amount of pressure drop
when the accessory
is used, adjust the
regulator following
the instructions in
the "Description of
Operation" paragraph in
the Operation Section.
NOTE: Adjust the
regulated pressure
under flow conditions
(while accessory
is being used).
Compressor is not
supplying enough air to
operate accessories.
Prolonged excessive
use of air.
Decrease amount
of air usage.
Compressor is not
large enough for
air requirement.
Check the accessory
air requirement. If
it is higher than the
SCFM or pressure
supplied by your air
compressor, you need
a larger compressor.
Hole in hose. Check and replace
if required.
Check valve restricted. Remove and clean,
or replace.
Air leaks. Tighten fittings.
Regulator knob has
continuous air leak.
Damaged regulator. Replace.
Regulator will not
shut off air outlet.
Damaged regulator. Replace.