Porter-Cable CPLDC2540P Air Compressor User Manual


 
18- ENG
A02231
SERVICE AND ADJUSTMENTS
Unit cycles automatically when power is on. When doing
Maintenance, you may be exposed to voltage sources,
compressed air or moving parts. Personal injuries can occur. Before performing
any Maintenance or repair, unplug the compressor and bleed off all air
pressure.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.
Before servicing:
Unplug or disconnect electrical supply to the air compressor.
Bleed tank of pressure.
Allow the air compressor to cool.
To Replace Regulator
1. Release all air pressure from air tank. See “To Drain Tank” in the
Maintenance section.
2. Unplug outfit.
3. Using an adjustable wrench remove the gauges and quick connect from
the regulator.
4. Remove the regulator.
5. Apply pipe sealant tape to the nipple on the pressure switch.
6. Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is pointing
in the direction of air flow.
7. Reapply pipe sealant to gauges and quick connect.
8. Reassemble gauges and quick connect. Orient
gauges to read correctly. Tighten quick connect with
wrench.
Arrow
Regulator