Porter-Cable DP350 Drill User Manual


 
11
Fig. 18A
FLEXIBLE LAMP
The flexible lamp operates independently of the drill
press. To turn the lamp “ON” and “OFF”, rotate switch
(A) Fig. 18A.
To reduce the risk of fire, use 40 watt or
less, 120 volt, reflector track type light bulb (not
supplied). A standard household light bulb should not be
used. The reflector track type light bulb should not
extend below the lamp shade.
A
Fig. 19
Fig. 20
Fig. 21
Fig. 22
A
B
D
C
E
Fig. 23
TABLE ADJUSTMENTS
1. The table can be raised or lowered on the drill press
column by loosening the table clamp (A) Fig. 19, and
turning the table raising and lowering handle (B) Fig. 20.
After the table is at the desired height, tighten clamp (A)
Fig. 19. NOTE: Final positioning of the drill press table
should always be from the bottom to the up position.
2. The table can be rotated 360 degrees on the column
by loosening clamp (A) Fig. 19, rotate table to desired
position and tighten clamp (A).
3. The table can be tilted right or left by pulling out and
removing table alignment pin (C) Fig. 21. NOTE: If pin (C)
is difficult to remove, turn nut (E) clockwise to pull pin
out of casting.
4. Fig. 22, illustrates the table alignment pin (C)
removed. Loosen table locking bolt (D), tilt table to the
desired angle and tighten bolt (D). When returning table
to the level position, replace table alignment pin (C). This
will position the table surface at 90 degrees to the
spindle.
5. A tilt scale (E) Fig. 23, is provided on the table
bracket casting to indicate the degree of tilt. A witness
line and zero mark (F) are also provided on the table to
line up with the scale (E).
D
C
F
E