If tool is used without an in-line oiler: place 5 or 6 drops of Porter-Cable Air Tool
Oil into the air inlet of the tool at the beginning of each workday.
SERVICE AND REPAIRS
All quality tools eventually require servicing or replacement of parts due to
wear from normal use. Some user serviceable components are described in
the TROUBLESHOOTING Section. Complete product Service is available from
either an AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-
CABLE SERVICE CENTER. All repairs made by these agencies are fully
guaranteed against defective material and workmanship. We cannot guarantee
repairs made or attempted by anyone other than these agencies.
Should you have any questions about your tool, feel free to write us at any time.
In any communications, please give all information shown on the nameplate of
your tool (model number, type, serial number, etc.).
TROUBLESHOOTING
CAUTION: Disconnect tool from air supply before performing any
Service Procedure.
SYMPTOM PROBLEMS SOLUTIONS
1. Air leak near top of Loose screws. Tighten screws.
tool or in trigger area. Worn or damaged Install “OVERHAUL” Maintenance Kit.
o-rings or seals.
2. Tool does nothing or Inadequate air supply. Verify adequate air supply.
operates sluggishly. Inadequate lubrication. Put 5 or 6 drops of oil into air inlet.
Worn or damaged Install
“DRIVER” Maintenance Kit.
o-rings or seals.
3. Air leak near bottom Loose screws. Tighten screws.
of tool. Worn or damaged Install “OVERHAUL” Maintenance Kit.
o-rings or bumper.
4. Tool jams frequently. Incorrect fasteners. Verify approved fasteners of
correct size.
Damaged fasteners. Replace w/undamaged fasteners.
Magazine or nose Tighten screws.
screws loose.
Magazine is dirty. Clean magazine.
Driver is worn or damaged. Install “DRIVER” Maintenance Kit.
5. Other. Contact a Porter-Cable
Service Facility.