Porter-Cable PCL120DD Cordless Drill User Manual


 
l
ithium-ion battery to an authorized PORTER-CABLE service center or to your local
retailer for recycling. You may also contact your local recycling center for information on
where to drop off the spent battery.
RBRC™ is a registered trademark of the Rechargeable Battery Recycling Corporation.
MAINTENANCE
Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the
tool; never immerse any part of the tool into a liquid.
REPLACEMENT PARTS
Use only identical replacement parts. For a parts list or to order parts, visit our service website at
www.portercable.com. You can also order parts from your nearest PORTER-CABLE Factory
Service Center or PORTER-CABLE Authorized Warranty Service Center. Or, you can call our
Customer Care Center at (888) 848-5175.
SERVICE AND REPAIRS
All quality tools will eventually require servicing and/or replacement of parts. For information about
PORTER-CABLE, its factory service centers or authorized warranty service centers, visit our
website at www.portercable.com or call our Customer Care Center at (888) 848-5175. All repairs
made by our service centers are fully guaranteed against defective material and workmanship. We
cannot guarantee repairs made or attempted by others.
You can also write to us for information at PORTER-CABLE, 4825 Highway 45 North, Jackson,
Tennessee 38305, (888) 848-5175 -Attention: Product Service. Be sure to include all of the
information shown on the nameplate of your tool (model number, type, serial number, etc.).
ACCESSORIES
WARNING: Since accessories, other than those offered by PORTER-CABLE,
have not been tested with this product, use of such accessories with this tool could be
hazardous. To reduce the risk of injury, only PORTER-CABLE recommended
accessories should be used with this product.
A complete line of accessories is available from your PORTER-CABLE Factory Service
Center or a PORTER-CABLE Authorized Warranty Service Center. Please visit our Web
Site www.portercable.com for a catalog or for the name of your nearest supplier.
11
Troubleshooting
Problem PossibleCause PossibleSolution
Unitwill notstart. Batterypack notinstalled properly. Checkbatterypack
installation.
Batterypack notcharged. Checkbattery pack
chargingrequirements.
Batterypack willnot charge. Batterypack notinserted intocharger. Insertbattery packinto
chargeruntilgreen LED
appears.
Chargernot pluggedin. Plugcharger intoa
workingoutlet. Referto
“ImportantChargingNotes”
formoredetails.
Surroundingair temperature Movecharger andbattery
toohotor toocold. packtoa surroundingair
temperatureofabove 40
degreesF(4.5°C) orbelow
105degreesF (+40.5°C).
Unitshuts offabruptly. Batterypack hasreached its •Allowbatterypack tocool
maximumthermallimit. down.
Outof charge.(To Placeon chargerand
maximizethelife ofthe allow tocharge.
batterypackitisdesigned
toshutoffabruptly when
thechargeis depleted.)
For assistance with your product, visit our website at www.portercable.com for a list of