PYLE Audio C6110 Air Compressor User Manual


 
11- ENG
A10244
Description of Operation
Become familiar with these controls before operating the unit.
On/Auto/Off Switch: Turn this switch
"On/Auto" to provide automatic
power to the pressure switch and
"Off" to remove power at the end of
each use.
Pressure Switch: The pressure
switch automatically starts the
motor when the air tank pressure
drops below the factory set "cut-in"
pressure. It stops the motor when the
air tank pressure reaches the factory
set "cut-out" pressure.
Safety Valve: If the pressure switch
does not shut off the air compressor
at its "cut-out" pressure setting, the
safety valve will protect against high
pressure by "popping out" at its factory set pressure (slightly higher than the
pressure switch "cut-out" setting).
Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure
available at the outlet side of the regulator. This pressure is controlled by the
regulator and is always less than or equal to the tank pressure.
Tank Pressure Gauge: The tank pressure gauge indicates the reserve air
pressure in the tank.
Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull
the knob out and turn clockwise to increase pressure and counterclockwise to
decrease pressure. When the desired pressure is reached push knob in to lock
in place.
Universal Quick-Connect Body: The universal quick-connect body accepts
the three most popular styles of quick-connect plugs: Industrial, automotive
(Tru-flate), and ARO. One hand push-to-connect operation makes connections
simple and easy.
Drain Valve: The drain valve is located at the base of the
air tank and is used to drain condensation at the end of
each use.
Cooling System (not shown): This compressor contains
an advanced design cooling system. At the heart of this
cooling system is an engineered fan. It is perfectly normal
for this fan to blow air through the vent holes in large amounts. You know that
the cooling system is working when air is being expelled.
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.
Safety
Valve
Regulator
Outlet
Pressure
Gauge
On/Auto/Off
Switch
Pressure
Switch
Tank
Pressure
Gauge
Universal
Quick-
Connect
Body
Drain
Valve