RayTek GP Stud Sensor User Manual


 
Spectral Response & Temperature Range:
Sensing Head Model: Spectral Response: Temperature Range:
GPR 8 to 14 microns -18 to 538°C (0 to 1000°F)
GPM 7.6 to 18 microns -18 to 538°C (0 to 1000°F)
System Accuracy (mA output) ±1% of measured value or ±1°C (2°F),
whichever is greater, @ 23°C ±5°C (73°F ±9°F)
System Repeatability ±0.5% of measured value or ±1°C (2°F) whichever is
greater
Response Time (95%):
GPR 700 mSec
GPM 1 Sec
Emissivity: 0.1 to 1.09 digitally adjustable increments of .01
Signal Processing: Peak/Valley Hold (up to 998 sec, 999=infinite hold
with external reset)
Variable averaging filter (up to 60 seconds)
T-ambient: fixed background ambient temperature
compensation
Outputs 4-digit, 7 segment LED display, °C/°F selectable
User configurable 4-20 mA current or thermocouple
output (J,K,E,N,R,S,T)
Two adjustable setpoints with deadbands controlling
+5 V alarm outputs or optional 3A mechanical relays
Power Supply 110/220 VAC, ±20%, 50-60 Hz
User configurable inputs for GPR, GPM, any 0-5 V
or 4-20 mA sensor, or thermocouple (J,K,E,N,R,S,T)
External Reset input to reset Peak/Valley hold
24 VDC/50 mA excitation voltage
Environmental Rating:
GP Monitor Front Panel IP 54 (IEC 529); NEMA-12
GPR Sensing Head IP 65 (IEC 529); NEMA-4*
GPM Sensing Head IP 65 (IEC 529); NEMA-4
* GPR rated with adapter and compression fitting
Ambient Temperature Range:
GP Monitor 0 to 50°C (32 to 120°F)
GPR Sensing Head: 0 to 65°C (32 to 150°F)
With optional water cooling 0 to 177°C (32 to 350°F)
GPM Sensing Head: 0 to 85°C (32 to 185°F)
With optional air cooling 0 to 200°C (32 to 392°F)
Storage Temperature -30 to 65°C (-22 to 150°F)
Relative Humidity 10 to 95%, non-condensing
GP Monitor Dimensions 1/8 DIN x 120 mm (1.75 x 3.63 x 4.75 in)
GP Monitor Weight 320 g (0.7 lbs)
Electrical Specifications
• Cooling housings for high ambient conditions
Air purge fittings for sensing heads
Adjustable mounting brackets and adapters
External isolated solid state relays for alarm outputs (10 Amp AC)
3A mechanical output relays
Raytek GP Series
Accessories / Options
General Specifications
17 (.67)
28 (1.1)
M 12x1
Ø 14 (.55)
11 (.43)
preinstalled cable
standard cable length 1 m ( 3 ft.)
Ø 5 (0.2)
mm (in)
Dimensions
Sensing Head—Optical Specifications
GPR Sensing Head
GPM Sensing Head
GPM Sensing Head
Optical Chart
GPR Sensing Head Optical Charts
(NOTE: nominal spot size based on 90% energy)
Measurement Specifications (Monitor w/ Sensing Head)
Raytek, the Raytek logo, and Thermalert are registered trademarks
of Raytek Corporation.
©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A
Specifications subject to change without notice. 3-1003
Worldwide Headquarters
Raytek Corporation
Santa Cruz, CA USA
Tel: 1 831 458 1110
800 227 8074 (U.S. and Canada only)
Fax: 1 831 458 1239
www.raytek.com
5710 Kenosha Street
Richmond, Illinois 60071 USA
Phone: +1 (815) 678-2211
FAX: +1 (815) 678-3961
Internet: www.watlow.com
e-mail: info@watlow.com
RIC-GP-0401
For Sales and Ordering Contact:
For Service and
W arranty Contact:
Your Authorized W atlow Distributor Is: