Schumacher 00-99-000835/1208 Battery Charger User Manual


 
6
ASSEMBLY INSTRUCTIONS9.
No assembly required.9.1
CONTROL PANEL10.
OPERATING INSTRUCTIONS11.
Connect the battery cable assembly to the INC-800A with the quick-con-11.1
nect connector on the back of the unit.
Connect the battery cable assembly to the battery as described in sections 11.2
6 and 7.
Plug the INC-800A into a 120V AC wall outlet.11.3
NOTE: The INC-800A intermittently draws more than 15 amps of current.
We recommend that you either install a 20 amp circuit or do not run any-
thing else on the same circuit as the INC-800A or you may trip the breaker
supplying the AC power.
Turn the 11.4 MAIN POWER switch to the ON position. When the charger pow-
ers up, the LCD screen defaults to and displays 12V FAST on the top line
and CONNECT BATTERY blinking on the bottom line. The charger also
checks for a properly connected battery. When it nds one, the display
changes to show the voltage of the battery on the top line and PRESS ON
blinking on the bottom line (referring to the CHARGE ON/OFF button).